Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 Fall;3(3):237-45.

Microtensile bond strength of eleven contemporary adhesives to dentin

Affiliations
  • PMID: 11803711
Comparative Study

Microtensile bond strength of eleven contemporary adhesives to dentin

S Inoue et al. J Adhes Dent. 2001 Fall.

Abstract

Purpose: To evaluate the microtensile bond strength (microTBS) of eleven contemporary adhesives to dentin, including three one-step self-etch systems, four two-step self-etch systems, three two-step total-etch systems, and one three-step total-etch system.

Materials and methods: Resin composite (Z100) was bonded to flat, mid-coronal dentin from 33 extracted human third molars using the adhesives strictly according to the respective manufacturer's instructions. After storage overnight in 37 degrees C water, the bonded specimens were sectioned into 3 to 6 slabs of approximately 1 mm thickness and 2.5 mm width. They were then trimmed into an hourglass shape resulting in an interface area of approximately 1 mm2, and subsequently subjected to microTBS testing with a crosshead speed of 1 mm/min.

Results: The microTBS varied from 30.0 MPa for the one-step self-etch adhesive Prompt L-Pop 2 (ESPE) to 63.1 MPa for the three-step total-etch adhesive OptiBond FL (Kerr), the latter being the only one that significantly differed from all other microTBS values. Although not significantly different, one-step self-etch adhesives tended to have lower microTBS than two-step self-etch and two-step total-etch adhesives. Specimen failures during sample preparation occurred with Prompt L-Pop 2 (4 pretesting failures out of 17 specimens) and NRC/Prime & Bond NT (7 pretesting failures out of 14 specimens).

Conclusion: Adhesives with simplified application procedures, either following a total-etch or self-etch approach, produced lower bond strengths to dentin than a conventional three-step total-etch adhesive. Some concern exists regarding the consistency in bonding effectiveness to dentin of some self-etch adhesives.

PubMed Disclaimer

Similar articles

Cited by

Publication types

Substances

LinkOut - more resources