Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 Oct;13(4 Suppl 1):120-8.

Early recovery of left ventricular function after stentless versus stented aortic valve replacement for pure aortic stenosis and severe cardiac dysfunction

Affiliations
  • PMID: 11805960
Comparative Study

Early recovery of left ventricular function after stentless versus stented aortic valve replacement for pure aortic stenosis and severe cardiac dysfunction

S Gelsomino et al. Semin Thorac Cardiovasc Surg. 2001 Oct.

Abstract

Objective: The aim of this study was to evaluate early recovery of systolic function after stentless aortic valve replacement (AVR) versus stented AVR.

Methods: Fifty-four consecutive patients with pure aortic stenosis and impaired left ventricular function (LVEF < or = 35%) were studied retrospectively. Aortic regurgitation, concomitant valvular or coronary artery surgery, atrial fibrillation, and a previous AVR were exclusion criteria. Twenty-two patients (mean age, 70.0 +/- 6.5 years) received a stentless bioprosthesis and 32 (mean age, 58.9 +/- 6.2 years, P =.031 between groups) a mechanical or stented biologic valve. Patients underwent echocardiography preoperatively, at discharge, at 6 months, and at 1 year after surgery.

Results: At 6 months, analysis of variance demonstrated significant differences between groups in fractional shortening measured at the endocardium and midwall fractional shortening (<0.001), velocity of circumferential shortening (P <.001) ejection fraction (P =.02), left ventricular mass index (P <.001), systolic meridional wall stress, and circumferential wall stress (P <.001), One-year studies confirmed these findings.

Conclusion: LV function showed, after a stentless AVR, an early recovery greater than in patients receiving a stented valve.