Survey of intraocular lens material and design
- PMID: 11807385
- DOI: 10.1097/00055735-200202000-00006
Survey of intraocular lens material and design
Abstract
Modern cataract surgery is constantly evolving and improving in terms of lens material and design. Researchers and physicians strive to obtain better refractive correction with smaller wound size and minimizing host cell response to limit the proliferation of lens epithelial cells leading to opacification of the lens capsule. Intraocular lens material varies in water content, refractive index, and tensile strength. Intraocular lens design has undergone revisions to prohibit lens epithelial cell migration and reflection of internal and external light. The evolution of intraocular lens and extracapsular cataract surgery has lead to faster postoperative recovery and better visual outcomes.
Similar articles
-
Posterior capsule opacification: is intraocular lens material a factor?Can J Ophthalmol. 2009 Apr;44(2):136-8. doi: 10.3129/i09-037. Can J Ophthalmol. 2009. PMID: 19491944 English, French. No abstract available.
-
Prevention of posterior capsule opacification using different intraocular lenses (results of one-year clinical study).Medicina (Kaunas). 2004;40(8):721-30. Medicina (Kaunas). 2004. PMID: 15299988 English, Lithuanian.
-
Posterior capsule opacity in Retinitis Pigmentosa according to different biomaterials of intraocular lenses: Our clinical experience.Clin Ter. 2015;166(5):191-3. doi: 10.7417/CT.2015.1876. Clin Ter. 2015. PMID: 26550807
-
Efficacy of different intraocular lens materials and optic edge designs in preventing posterior capsular opacification: a meta-analysis.Am J Ophthalmol. 2007 Mar;143(3):428-36. doi: 10.1016/j.ajo.2006.11.045. Epub 2006 Dec 28. Am J Ophthalmol. 2007. PMID: 17224119
-
[Lens platform].Klin Oczna. 2010;112(7-9):257-62. Klin Oczna. 2010. PMID: 21121131 Review. Polish.
Cited by
-
Haptic fracture and dislocation of polyimide intraocular lens after neodymium: YAG laser capsulotomy: A case report.Medicine (Baltimore). 2019 May;98(20):e15720. doi: 10.1097/MD.0000000000015720. Medicine (Baltimore). 2019. PMID: 31096526 Free PMC article.
-
Surgical and visual outcomes following exchange of opacified Hydroview intraocular lenses.Br J Ophthalmol. 2007 Mar;91(3):299-302. doi: 10.1136/bjo.2006.095414. Epub 2006 Oct 31. Br J Ophthalmol. 2007. PMID: 17077119 Free PMC article.
-
Outcome of phacoemulsification in patients with uveitis.Br J Ophthalmol. 2007 Jul;91(7):916-21. doi: 10.1136/bjo.2007.114801. Epub 2007 Jan 17. Br J Ophthalmol. 2007. PMID: 17229800 Free PMC article.
-
Measurement of Force Required for Anterior Displacement of Intraocular Lenses and Its Defining Parameters.Materials (Basel). 2020 Oct 15;13(20):4593. doi: 10.3390/ma13204593. Materials (Basel). 2020. PMID: 33076490 Free PMC article.
-
Lens epithelial cell response to atmospheric pressure plasma modified poly(methylmethacrylate) surfaces.J Mater Sci Mater Med. 2010 May;21(5):1703-12. doi: 10.1007/s10856-010-4030-8. Epub 2010 Feb 27. J Mater Sci Mater Med. 2010. PMID: 20195888
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources