A new radial mechanical puncture echoendoscope: prospective comparison with standard linear and radial echoendoscopes in assessment of focal pancreatic lesions
- PMID: 11818934
- DOI: 10.1067/mge.2002.120890
A new radial mechanical puncture echoendoscope: prospective comparison with standard linear and radial echoendoscopes in assessment of focal pancreatic lesions
Abstract
Background: A new mechanical puncture-echoendoscope was evaluated by comparing it with conventional linear and radial echoendoscopes. The new instrument has a 300 degrees image field parallel to the axis of the echoendoscope, which could potentially improve accuracy and facilitate assessment of suspected pancreatic lesions before needle puncture.
Methods: Twenty consecutive patients with suspected pancreatic lesions were evaluated endosonographically, including fine needle aspiration (FNA). The initial assessment was performed by random selection of either the new instrument or the standard linear echoendoscope. After completing the assessment including FNA, the procedure with FNA was repeated with the other puncture echoendoscope. The findings with these 2 instruments were compared to those with the conventional radial scanning echoendoscope.
Results: FNA was performed in 17 patients with pancreatic head lesions. In 3 patients without a visible pancreatic mass lymph, nodes greater than 10 mm in diameter were aspirated. The ability to image the needle, number of punctures, and material obtained were comparable for both puncture echoendoscopes. There were no significant differences with regard to time required for FNA with both puncture echoendoscopes or in the assessment of surrounding structures with all 3 instruments. The results of cytopathologic evaluation of material obtained by FNA were similar in 15 cases. The new instrument could not be passed into the esophagus in 1 patient because of an esophageal stricture.
Conclusions: The performance of the new mechanical puncture echoendoscope was satisfactory for assessment and FNA of pancreatic lesions. The additional use of the conventional radial scanning echoendoscope provided no advantage with regard to any parameter assessed.
Similar articles
-
Newly developed all in one EUS system: one cart system, forward-viewing optics type 360 degrees electronic radial array echoendoscope and oblique-viewing type convex array echoendoscope.Fukuoka Igaku Zasshi. 2007 Mar;98(3):82-9. Fukuoka Igaku Zasshi. 2007. PMID: 17461033
-
Endosonographically guided transduodenal and transgastral fine-needle aspiration puncture of focal pancreatic lesions.Bildgebung. 1995 Jun;62(2):110-5. Bildgebung. 1995. PMID: 7663134
-
Forward-viewing versus oblique-viewing echoendoscopes in the diagnosis of upper GI subepithelial lesions with EUS-guided FNA: a prospective, randomized, crossover study.Gastrointest Endosc. 2015 Aug;82(2):287-95. doi: 10.1016/j.gie.2014.12.051. Epub 2015 Mar 25. Gastrointest Endosc. 2015. PMID: 25816723 Clinical Trial.
-
Pretherapeutic evaluation of patients with upper gastrointestinal tract cancer using endoscopic and laparoscopic ultrasonography.Dan Med J. 2012 Dec;59(12):B4568. Dan Med J. 2012. PMID: 23290296 Review.
-
[Endoscopic ultrasound-fine needle aspiration (EUS-FNA) for pancreatic lesions: effectiveness in clinical practice].Minerva Med. 2007 Aug;98(4):339-42. Minerva Med. 2007. PMID: 17921947 Review. Italian.
Cited by
-
Imaging modalities for characterising focal pancreatic lesions.Cochrane Database Syst Rev. 2017 Apr 17;4(4):CD010213. doi: 10.1002/14651858.CD010213.pub2. Cochrane Database Syst Rev. 2017. PMID: 28415140 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical