There is limited data currently available for making dose and risk assessments for paediatric patients undergoing computed tomographic examination. A method has been developed to correlate the risk-related quantity, effective dose, to the more simply derived quantity dose-length product. This involved scanning a series of paediatric anthropomorphic phantoms containing thermoluminescent dosimeters to measure effective dose for scans of various anatomic regions. The quantity effective dose per dose-length product was calculated and plotted as a function of patient size. This showed a simple exponential relationship, and equations of fit were derived to enable the calculation of effective dose for a patient of any size. Measurements carried out on a second scanner and for alternative scan volumes indicated that the method could be generally utilized.
Similar articles
-
On the use of Monte Carlo-derived dosimetric data in the estimation of patient dose from CT examinations.Med Phys. 2008 May;35(5):2018-28. doi: 10.1118/1.2896075. Med Phys. 2008. PMID: 18561678
-
Generating and using patient-specific whole-body models for organ dose estimates in CT with increased accuracy: feasibility and validation.Phys Med. 2014 Dec;30(8):925-33. doi: 10.1016/j.ejmp.2014.09.005. Epub 2014 Oct 5. Phys Med. 2014. PMID: 25288527
-
Assessment of organ absorbed doses and estimation of effective doses from pediatric anthropomorphic phantom measurements for multi-detector row CT with and without automatic exposure control.Health Phys. 2009 Oct;97(4):303-14. doi: 10.1097/HP.0b013e3181ad00ed. Health Phys. 2009. PMID: 19741359
-
Influence of phantom diameter, kVp and scan mode upon computed tomography dose index.Med Phys. 2003 Mar;30(3):395-402. doi: 10.1118/1.1543149. Med Phys. 2003. PMID: 12674240
-
Comparison of organ dosimetry methods and effective dose calculation methods for paediatric CT.Australas Phys Eng Sci Med. 2012 Jun;35(2):117-34. doi: 10.1007/s13246-012-0134-4. Epub 2012 Apr 11. Australas Phys Eng Sci Med. 2012. PMID: 22492218 Review.
Cited by
-
Radiation doses with various body weights of phantoms in brain 128-slice MDCT examination.J Radiat Res. 2019 Jul 1;60(4):466-475. doi: 10.1093/jrr/rrz029. J Radiat Res. 2019. PMID: 31197311 Free PMC article.
-
Patient doses from CT examinations in Turkey.Diagn Interv Radiol. 2015 Sep-Oct;21(5):428-34. doi: 10.5152/dir.2015.14306. Diagn Interv Radiol. 2015. PMID: 26133189 Free PMC article.
-
Patient-specific dose estimation for pediatric chest CT.Med Phys. 2008 Dec;35(12):5821-8. doi: 10.1118/1.3026593. Med Phys. 2008. PMID: 19175138 Free PMC article.
-
Coronary imaging techniques with emphasis on CT and MRI.Pediatr Radiol. 2011 Dec;41(12):1516-25. doi: 10.1007/s00247-011-2222-0. Epub 2011 Nov 30. Pediatr Radiol. 2011. PMID: 22127683 Review.
-
Development of CT Effective Dose Conversion Factors from Clinical CT Examinations in the Republic of Korea.Diagnostics (Basel). 2020 Sep 21;10(9):727. doi: 10.3390/diagnostics10090727. Diagnostics (Basel). 2020. PMID: 32967352 Free PMC article.