Abstract
In this study 39 male and female cadaveric femoral necks of ages between 21 and 89 years have been radiographed and subsequently mechanically tested to determine failure load. A structural model has been developed, in an attempt to predict the failure load of specimens solely from measurements made from an anteroposterior radiograph of the neck region. Good correlation was obtained between the predicted and experimental values for the range tested. The influence of average bone porosity is discussed. It is believed that this method, with modifications will provide a basis for the quantitative assessment of femoral neck strength in the clinical situation.
Similar articles
-
[Radiologic differentiation between pathologic osteoporosis and bone atrophy due to age (author's transl)].Z Orthop Ihre Grenzgeb. 1975 Dec;113(6):1079-81. Z Orthop Ihre Grenzgeb. 1975. PMID: 766438 Clinical Trial. German.
-
Effect of local density changes on the failure load of the proximal femur.J Orthop Res. 1999 Sep;17(5):661-7. doi: 10.1002/jor.1100170507. J Orthop Res. 1999. PMID: 10569474
-
Bone pattern of the femoral neck as a measure of bone density and susceptibility to hip fractures.Ann Clin Res. 1969 May;1(1):85-7. Ann Clin Res. 1969. PMID: 5350773 No abstract available.
-
Evaluation of the Singh index and femoral calcar width as epidemiological methods for measuring bone mass in the femoral neck.Clin Radiol. 1986 Mar;37(2):123-5. doi: 10.1016/s0009-9260(86)80378-6. Clin Radiol. 1986. PMID: 3698493
-
[Diagnosis and differential diagnosis of osteoporosis of old age].Dtsch Med Wochenschr. 1977 Jun 10;102(23):871-4. doi: 10.1055/s-0028-1104981. Dtsch Med Wochenschr. 1977. PMID: 68860 Review. German. No abstract available.
Cited by
-
Dual energy X-ray absorptiometry is also an accurate and precise method to measure the dimensions of human long bones.Calcif Tissue Int. 1994 Feb;54(2):101-5. doi: 10.1007/BF00296059. Calcif Tissue Int. 1994. PMID: 8012864
-
Investigation of load transfer and optimum pin configuration in the internal fixation, by Muller screws, of fractured femoral necks.Med Biol Eng Comput. 1980 May;18(3):319-25. doi: 10.1007/BF02443386. Med Biol Eng Comput. 1980. PMID: 7421314 No abstract available.
-
Advances in the noninvasive assessment of bone density, quality, and structure.Calcif Tissue Int. 1996;59 Suppl 1:S10-5. doi: 10.1007/s002239900169. Calcif Tissue Int. 1996. PMID: 8974723
-
Morphological analysis of the proximal femur using quantitative computed tomography.Int Orthop. 2007 Jun;31(3):287-92. doi: 10.1007/s00264-006-0182-z. Epub 2006 Aug 2. Int Orthop. 2007. PMID: 16896872 Free PMC article.
-
Hip geometry and its role in fracture: what do we know so far?Curr Osteoporos Rep. 2003 Jun;1(1):25-31. doi: 10.1007/s11914-003-0005-8. Curr Osteoporos Rep. 2003. PMID: 16036062 Review.