Clinical Trial
. 2002 Feb 5;105(5):583-8.
doi: 10.1161/hc0502.103347.

Rotational atherectomy does not reduce recurrent in-stent restenosis: results of the angioplasty versus rotational atherectomy for treatment of diffuse in-stent restenosis trial (ARTIST)

Affiliations
Clinical Trial

Rotational atherectomy does not reduce recurrent in-stent restenosis: results of the angioplasty versus rotational atherectomy for treatment of diffuse in-stent restenosis trial (ARTIST)

Juergen vom Dahl et al. Circulation. .

Abstract

Background: Aim of this trial was to compare rotational atherectomy followed by balloon angioplasty (rotablation [ROTA] group) with balloon angioplasty (percutaneous transluminal coronary angioplasty [PTCA] group) alone in patients with diffuse in-stent restenosis.

Methods and results: The ARTIST study is a multicenter, randomized, prospective European trial with 298 patients with in-stent restenosis>70% (mean lesion length, 14 +/- 8 mm) in stents, implanted in coronary arteries for >/= 3 months. In the PTCA group, angioplasty was performed at the discretion of the local investigator, and rotablation was performed by using a stepped-burr approach followed by adjunctive PTCA with low (</= 6 atm) inflation pressure. Intravascular ultrasound during the intervention and at follow-up was used in a substudy in 86 patients (45 PTCA, 41 ROTA). Angiography demonstrated no difference regarding the short-term outcome, with equivalent procedural success rates defined as remaining stenosis <30% (89% PTCA, 88% ROTA). However, the results showed that, in the long term, PTCA was a significantly better strategy than ROTA. Mean net gain in minimal lumen diameter was 0.67 mm and 0.45 mm for PTCA and ROTA, respectively (P=0.0019). Mean gain in diameter stenosis was 25% and 17% (P=0.002), resulting in restenosis (>/= 50%) rates of 51% (PTCA) and 65% (ROTA) (P=0.039). By intravascular ultrasound, the major difference was the missing stent over-expansion during PTCA after ROTA. Six-month event-free survival was significantly higher after PTCA (91.3%) compared with ROTA (79.6%, P=0.0052).

Conclusions: In terms of the primary objective of the study, PTCA produced a significantly better long-term outcome than ROTA followed by adjunctive low-pressure PTCA.