Evaluation of kinetic light scattering as an approach to the measurement of specific proteins with the centrifugal analyzer. I. Methodology
- PMID: 1182992
Evaluation of kinetic light scattering as an approach to the measurement of specific proteins with the centrifugal analyzer. I. Methodology
Abstract
A laser-modified centrifugal analyzer was used to develop kinetic light scattering methods for the measurement of human immunoglobulins IgG, IgA, and IgM. Comparison of equilibrium light scattering methods with kinetic procedures for IgG and IgA demonstrate equivalent precision and relative accuracy. However, quantitative results obtained by equilibrium and kinetics methods for IgM were found to differ significantly. Recovery studies performed with purified IgM have shown that both methods can yield quantitative results in the normal range. Our observations demonstrate that the technique offers a viable and in some respects a superior alternative to other methods currently used in the clinical laboratory.
Similar articles
-
Evaluation of kinetic light scattering as an approach to the measurement of specific proteins with the centrifugal analyzer. II. Theoretical considerations.Clin Chem. 1975 Nov;21(12):1735-46. Clin Chem. 1975. PMID: 1182993
-
Comparison of turbidimetric and light-scattering measurements of immunoglobulins by use of a centrifugal analyzer with absorbance and fluorescence/light-scattering optics.Clin Chem. 1980 Sep;26(10):1459-66. Clin Chem. 1980. PMID: 7408174
-
Immunochemical determination of human immunoglobulins: use of kinetic turbidimetry and a 36-place centrifugal analyzer.Clin Chem. 1979 Apr;25(4):526-30. Clin Chem. 1979. PMID: 466760
-
[Serum immunoglobulins (IgG, IgA, IgM) in chronic bronchitis in the industrial environment].Med Interne. 1981 Apr-Jun;19(2):191-8. Med Interne. 1981. PMID: 6764021 Review. French. No abstract available.
-
The use of a centrifugal fast analyzer for biochemical and immunological analysis.Methods Biochem Anal. 1976;23(0):189-248. doi: 10.1002/9780470110430.ch3. Methods Biochem Anal. 1976. PMID: 794627 Review. No abstract available.
Cited by
-
Development and validation of 14 human serum protein assays on the Roche cobas® c 501.J Clin Lab Anal. 2011;25(1):52-60. doi: 10.1002/jcla.20430. J Clin Lab Anal. 2011. PMID: 21254244 Free PMC article.
-
Rate nephelometric determination of rheumatoid factor: comparison between Kallestad QM-300 and Beckman ICS-II (RF) methods.J Clin Pathol. 1990 Mar;43(3):243-5. doi: 10.1136/jcp.43.3.243. J Clin Pathol. 1990. PMID: 2332520 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources
Miscellaneous