Comparison of non-diglyceride- and diglyceride-based assays for pancreatic lipase activity
- PMID: 11835532
- PMCID: PMC6807806
- DOI: 10.1002/jcla.2023
Comparison of non-diglyceride- and diglyceride-based assays for pancreatic lipase activity
Abstract
Pancreatic lipase is produced and stored in pancreatic acinar cells, and is normally secreted into the duct system. In disorders that cause pancreatic damage, pancreatic lipase enters the circulation, and serum lipase activity becomes useful in the diagnosis and evaluation of pancreatitis. During the last decade, many lipase assays have used the Imamura method, in which a series of enzymatic reactions utilizing a diglyceride substrate leads to the formation of a colorimetrically detected product. Historically, this method has been prone to significant interference from various substances, including glycerol itself. In the light of these limitations, we evaluated an automated enzymatic rate assay that uses a non-diglyceride-based, pancreatic lipase-specific substrate. Precision, linearity, and potential interference were assessed, and when compared to the Imamura method, the non-diglyceride-based assay exhibited a slope of 0.475, y-intercept of 15.89, r-value of 0.9516, and S(y,x) of 12.96. Similar results were also observed when the two assays were compared using samples with markedly elevated creatinine levels. Between-day coefficients of variance (CVs) ranged from 5.0% to 5.5%, which compared well with the diglyceride-based method, and linearity spanned a range of 3-156 U/L. Evaluation of over 2,000 patient results collected during a 6-month period suggested that the manufacturer's upper reference limit of 51 U/L may be too conservative. No significant interference was identified with bilirubin, triglyceride, or glycerol itself, and significant interference from hemoglobin was observed only at concentrations of 116 mg/dL or greater. As a result, the non-diglyceride-based method provides an acceptable alternative for the routine laboratory measurement of lipase activity.
Copyright 2002 Wiley‐Liss, Inc.
Similar articles
-
Clinical and analytical evaluation of a continuous enzymatic method for measuring pancreatic lipase activity.Clin Chem. 1993 Feb;39(2):304-8. Clin Chem. 1993. PMID: 8381733
-
Validation and diagnostic efficacy of a lipase assay using the substrate 1,2-o-dilauryl-rac-glycero glutaric acid-(6' methyl resorufin)-ester for the diagnosis of acute pancreatitis in dogs.Vet Clin Pathol. 2005;34(1):39-43. doi: 10.1111/j.1939-165x.2005.tb00007.x. Vet Clin Pathol. 2005. PMID: 15732016
-
Determination of the kinetic properties of platycodin D for the inhibition of pancreatic lipase using a 1,2-diglyceride-based colorimetric assay.Arch Pharm Res. 2004 Sep;27(9):968-72. doi: 10.1007/BF02975852. Arch Pharm Res. 2004. PMID: 15473669
-
Triglyceride lipase assays based on a novel fluorogenic alkyldiacyl glycerol substrate.Methods Mol Biol. 1999;109:19-29. doi: 10.1385/1-59259-581-2:19. Methods Mol Biol. 1999. PMID: 9918008 Review. No abstract available.
-
Experiences with a new assay for pancreas specific alpha-amylase.Ann Biol Clin (Paris). 1990;48(2):91-7. Ann Biol Clin (Paris). 1990. PMID: 2188534 Review.
Cited by
-
Biochemical alterations induced by Zn and Cd individually or in combination in the serum of Oreochromis niloticus.Fish Physiol Biochem. 2010 Sep;36(3):647-653. doi: 10.1007/s10695-009-9337-3. Epub 2009 Jun 13. Fish Physiol Biochem. 2010. PMID: 19526320
-
Enzymatic determination of diglyceride using an iridium nano-particle based single use, disposable biosensor.Sensors (Basel). 2010;10(6):5758-73. doi: 10.3390/s100605758. Epub 2010 Jun 8. Sensors (Basel). 2010. PMID: 22219685 Free PMC article.
References
-
- Tietz NW, Shuey DF. 1993. Lipase in serum—the elusive enzyme: an overview. Clin Chem 39:746–756. - PubMed
-
- Lott JA, Patel ST, Sawhney AK, Kazmierczak, Love JE Jr. 1986. Assays of serum lipase: analytical and clinical considerations. Clin Chem 32:1290–1302. - PubMed
-
- Tietz NW. 1988. Amylase measurements in serum—old myths die hard [Editorial]. J Clin Chem Clin Biochem 26:251–253. - PubMed
-
- Melzi d’Eril GV, Bosoni T, Moratti R, Ventrucci M, Fumagalli A, Tarenghi G. 1992. Clinical validity of a continuous colorimetric method for serum lipase. Eur J Clin Chem Biochem 30:439–444. - PubMed
-
- Imamura S, Hirayama T, Arai T, Takao K, Misaki H. 1989. An enzymatic method using 1,2‐diglyceride for pancreatic lipase test in serum [Abstract]. Clin Chem 35:1126.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials