An evaluation of retrofit engineering control interventions to reduce perchloroethylene exposures in commercial dry-cleaning shops
- PMID: 11843196
- DOI: 10.1080/104732202317201348
An evaluation of retrofit engineering control interventions to reduce perchloroethylene exposures in commercial dry-cleaning shops
Abstract
Real-time monitoring was used to evaluate the ability of engineering control devices retrofitted on two existing dry-cleaning machines to reduce worker exposures to perchloroethylene. In one dry-cleaning shop, a refrigerated condenser was installed on a machine that had a water-cooled condenser to reduce the air temperature, improve vapor recovery, and lower exposures. In a second shop, a carbon adsorber was retrofitted on a machine to adsorb residual perchloroethylene not collected by the existing refrigerated condenser to improve vapor recovery and reduce exposures. Both controls were successful at reducing the perchloroethylene exposures of the dry-cleaning machine operator. Real-time monitoring was performed to evaluate how the engineering controls affected exposures during loading and unloading the dry-cleaning machine, a task generally considered to account for the highest exposures. The real-time monitoring showed that dramatic reductions occurred in exposures during loading and unloading of the dry-cleaning machine due to the engineering controls. Peak operator exposures during loading and unloading were reduced by 60 percent in the shop that had a refrigerated condenser installed on the dry-cleaning machine and 92 percent in the shop that had a carbon adsorber installed. Although loading and unloading exposures were dramatically reduced, drops in full-shift time-weighted average (TWA) exposures were less dramatic. TWA exposures to perchloroethylene, as measured by conventional air sampling, showed smaller reductions in operator exposures of 28 percent or less. Differences between exposure results from real-time and conventional air sampling very likely resulted from other uncontrolled sources of exposure, differences in shop general ventilation before and after the control was installed, relatively small sample sizes, and experimental variability inherent in field research. Although there were some difficulties and complications with installation and maintenance of the engineering controls, this study showed that retrofitting engineering controls may be a feasible option for some dry-cleaning shop owners to reduce worker exposures to perchloroethylene. By installing retrofit controls, a dry-cleaning facility can reduce exposures, in some cases dramatically, and bring operators into compliance with the Occupational Safety and Health Administration (OSHA) peak exposure limit of 300 ppm. Retrofit engineering controls are also likely to enable many dry-cleaning workers to lower their overall personal TWA exposures to perchloroethylene.
Similar articles
-
Effects of retrofit emission controls and work practices on perchloroethylene exposures in small dry-cleaning shops.Appl Occup Environ Hyg. 2002 Feb;17(2):112-20. doi: 10.1080/104732202317201357. Appl Occup Environ Hyg. 2002. PMID: 11843197
-
A control technology evaluation of state-of-the-art, perchloroethylene dry-cleaning machines.Appl Occup Environ Hyg. 2002 May;17(5):352-9. doi: 10.1080/10473220252864950. Appl Occup Environ Hyg. 2002. PMID: 12018399
-
Perchloroethylene exposure assessment among dry cleaning workers.Am Ind Hyg Assoc J. 1990 Oct;51(10):566-74. doi: 10.1080/15298669091370112. Am Ind Hyg Assoc J. 1990. PMID: 2251984
-
A review of historical exposures to asbestos among skilled craftsmen (1940-2006).J Toxicol Environ Health B Crit Rev. 2007 Sep-Oct;10(5):319-77. doi: 10.1080/10937400601034191. J Toxicol Environ Health B Crit Rev. 2007. PMID: 17687724 Review.
-
Occupational exposures and cancer risk in commercial laundry and dry cleaning industries: a scoping review.BMC Public Health. 2023 Dec 21;23(1):2561. doi: 10.1186/s12889-023-17306-y. BMC Public Health. 2023. PMID: 38129859 Free PMC article.
Cited by
-
Tetrachloroethylene (PCE, Perc) levels in residential dry cleaner buildings in diverse communities in New York City.Environ Health Perspect. 2005 Oct;113(10):1336-43. doi: 10.1289/ehp.7414. Environ Health Perspect. 2005. PMID: 16203243 Free PMC article.
-
Effectiveness of health and safety in small enterprises: a systematic review of quantitative evaluations of interventions.J Occup Rehabil. 2010 Jun;20(2):163-79. doi: 10.1007/s10926-009-9212-1. J Occup Rehabil. 2010. PMID: 19908131
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical