Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2002 Jan-Feb;9(1):52-62.
doi: 10.1067/mnc.2002.119252.

Improved coronary disease detection with quantitative attenuation-corrected Tl-201 images

Affiliations
Comparative Study

Improved coronary disease detection with quantitative attenuation-corrected Tl-201 images

Mathew Shotwell et al. J Nucl Cardiol. 2002 Jan-Feb.

Abstract

Background: The normal distribution of myocardial tracer activity is different in attenuation-corrected images compared with uncorrected images. We therefore postulated that quantitation of attenuation-corrected thallium 201 images with direct comparison to a database of healthy subjects could improve detection of coronary artery stenoses.

Methods and results: In 49 patients with angiographic evidence of coronary artery disease and 69 patients with a less than 5% likelihood of coronary artery disease, tomographic Tl-201 myocardial imaging was performed by means of a triple-headed camera with fan-beam collimators and the images were processed with attenuation correction, with attenuation and Compton scatter correction, and without correction. Images were subjectively interpreted in a blinded manner. From the group of 69 patients with a low likelihood of coronary disease, scintigraphic data from the first 20 men and the first 20 women were used to generate normal reference ranges for each of the 3 image-processing methods. Data from the 49 patients with angiographic coronary disease and from the remaining 29 patients with a low likelihood of coronary disease were then analyzed quantitatively in comparison to the gender-matched normal databases. With visual interpretation, attenuation-corrected images yielded an improved detection rate compared with uncorrected images (79% vs 46%, P =.008) for 70% or greater left anterior descending coronary artery stenoses. Attenuation-corrected images also provided an improved normalcy rate for the right coronary artery territory (91% vs 75%, P =.006) and an improved normalcy rate when the images were analyzed overall by patient (88% vs 74%, P =.009). With quantitative analysis, attenuation correction yielded an improved detection rate for patients with a significant coronary artery stenosis compared with uncorrected images (90% vs 71%, P =.016). Defect extent was also increased by attenuation correction. Compared with attenuation correction alone, the addition of scatter correction yielded no incremental improvement in detection rate or normalcy rate. Attenuation-scatter correction did produce a nonsignificant trend toward detection of more of the total number of stenotic arteries compared with uncorrected images (60 vs 48 of 79 arteries).

Conclusions: With the use of a triple-headed camera with fan-beam collimation, visual analysis of attenuation-corrected Tl-201 images improved detection of left anterior descending coronary artery disease without loss of detection in other coronary territories. Furthermore, quantitative analysis of attenuation-corrected Tl-201 images improved the overall detection rate for coronary artery disease in patients without compromise of the normalcy rate.

PubMed Disclaimer

References

    1. J Nucl Med. 1995 Jun;36(6):921-31 - PubMed
    1. J Nucl Med. 1990 Jul;31(7):1168-79 - PubMed
    1. J Nucl Cardiol. 1998 Jul-Aug;5(4):369-77 - PubMed
    1. J Nucl Med. 1999 Aug;40(8):1301-9 - PubMed
    1. Eur J Nucl Med. 1998 Mar;25(3):220-8 - PubMed

Publication types

LinkOut - more resources