Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Jan;87(1):7-12.

Risk of venous thromboembolism recurrence: high negative predictive value of D-dimer performed after oral anticoagulation is stopped

Affiliations
  • PMID: 11848459

Risk of venous thromboembolism recurrence: high negative predictive value of D-dimer performed after oral anticoagulation is stopped

Gualtiero Palareti et al. Thromb Haemost. 2002 Jan.

Abstract

In some patients with previous venous thromboembolism (VTE) D-dimer levels (D-Dimer) tend to increase after oral anticoagulant therapy (OAT) is stopped. The aim of our study was to evaluate the predictive value of D-Dimer for the risk of VTE recurrence after OAT withdrawal. After a first episode of deep vein thrombosis (DVT) of the lower limbs and/or pulmonary embolism (PE), 396 patients (median age 67 years, 198 males) were followed from the day of OAT discontinuation for 21 months. D-dimer was measured on the day of OAT withdrawal (T1), 3-4 weeks (T2) and 3 months (+/- 10 days, T3) thereafter. The main outcome events of the study were: objectively documented recurrent DVT and/or PE. D-dimer was found to be increased in 15.5%, 40.3% and 46.2% of the patients at T1, T2 and T3, respectively. In 199 (50.2%) patients, D-dimer levels were elevated in at least one measurement. During a follow-up of 628.4 years, 40 recurrences were recorded (10.1% of patients; 6.4% patient-years of follow-up). D-dimer was increased in at least one measurement in 28 of these cases, but remained normal in 11 subjects (three of whom had recurrent events triggered by circumstantial factors, three with malignancy-associated factors) (in one subject D-dimer was not measured). The negative predictive value (NPV) of D-dimer was 95.6% (95% CI 91.6-98.1) at T3 and was even higher (96.7%; 95% CI 92.9-98.8) after exclusion of the six recurrences due to circumstantial factors. Only five idiopathic recurrences occurred in the 186 patients with consistently normal D-dimer. In conclusion, D-dimer has a high NPV for VTE recurrence when performed after OAT discontinuation.

PubMed Disclaimer

Comment in

MeSH terms