Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2002 Feb;77(2 Suppl 2):S13-8.
doi: 10.1016/s0015-0282(01)03275-7.

Contraceptive efficacy and cycle control with the Ortho Evra/Evra transdermal system: the analysis of pooled data

Affiliations
Free article
Clinical Trial

Contraceptive efficacy and cycle control with the Ortho Evra/Evra transdermal system: the analysis of pooled data

Miriam Zieman et al. Fertil Steril. 2002 Feb.
Free article

Abstract

Objective: To present efficacy and cycle control data pooled from three pivotal studies of the contraceptive patch (Ortho Evra/Evra).

Design: Three multicenter, open-label, contraceptive studies that included up to 13 treatment cycles.

Setting: 183 centers.

Patient(s): 3,319 women.

Intervention(s): Three consecutive 7-day patches (21 days) with 1 patch-free week per cycle.

Main outcome measure(s): Contraceptive efficacy and cycle control.

Result(s): Overall and method failure life-table estimates of contraceptive failure through 13 cycles were 0.8% (95% CI, 0.3%-1.3%) and 0.6% (95% CI, 0.2%-0.9%), respectively. Corresponding Pearl indices were 0.88 (95% CI, 0.44-1.33) and 0.7 (95% CI, 0.31-1.10). Contraceptive failure among women with a body weight < 90 kg (<198 lb) was low and uniformly distributed across the weight range. A subgroup of women with body weight > or = 90 kg (> or = 198 lb) may have increased risk of pregnancy. The incidence of breakthrough bleeding was low and decreased over time.

Conclusion(s): In contraceptive patch users, the overall annual probability of pregnancy was 0.8% and the method failure probability was 0.6%. The efficacy of the patch was high and similar across age and racial groups. Among women < 90 kg (<198 lb), contraceptive failure was low and uniformly distributed across the range of body weights. In women > or = 90 kg (> or = 198 lb), contraceptive failures may be increased. Efficacy and cycle control have been shown to be comparable to an established oral contraceptive.

PubMed Disclaimer

Publication types