Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2001 Nov-Dec;14(6):425-31.
doi: 10.1046/j.1525-139x.2001.00106.x.

Catheter performance

Affiliations
Review

Catheter performance

T A Depner. Semin Dial. 2001 Nov-Dec.

Abstract

Venous catheters differ from peripheral arteriovenous (AV) access devices in many important ways. This discussion focuses on their performance as a conduit for blood flow between the patient and the dialyzer and on how catheter function is both limited and enhanced relative to the more common peripheral accesses. Catheter flow is limited by the high resistance inherent in the extended length of venous catheters relative to dialysis needles, but the high rate of flow in central veins also diminishes the opportunity for access recirculation. Cardiopulmonary recirculation is absent in patients with catheter access unless the patient also has a peripheral access. In the latter case, the same detrimental effect on urea clearance is seen regardless of which access device is used. Flow-dependent recirculation through circuits other than the peripheral AV access reduces the efficiency of dialysis (regardless of the type of access, catheter, or peripheral AV device used) across both catheters and peripheral AV devices. The inside diameter of the catheter plays a sensitive role in determining catheter resistance to flow. Slight increases in diameter under the same pressure head are associated with large increases in flow. Negative pressure at the catheter inflow port generated by the blood pump is magnified relative to peripheral devices, predisposing to partial collapse of the pump tubing segment and erroneous blood flow readings by the pump motor speed indicator. Setting a limit on prepump negative pressure can minimize this error. Future applications of dialysis may require lower pump speeds, which would allow more liberal use of catheter access if their potential for infection and clotting can be reduced.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources