New algorithms for processing and peak detection in liquid chromatography/mass spectrometry data
- PMID: 11857732
- DOI: 10.1002/rcm.600
New algorithms for processing and peak detection in liquid chromatography/mass spectrometry data
Abstract
Two new algorithms for automated processing of liquid chromatography/mass spectrometry (LC/MS) data are presented. These algorithms were developed from an analysis of the noise and artifact distribution in such data. The noise distribution was analyzed by preparing histograms of the signal intensity in LC/MS data. These histograms are well fit by a sum of two normal distributions in the log scale. One new algorithm, median filtering, provides increased performance compared to averaging adjacent scans in removing noise that is not normally distributed in the linear scale. Another new algorithm, vectorized peak detection, provides increased robustness with respect to variation in the noise and artifact distribution compared to methods based on determining an intensity threshold for the entire dataset. Vectorized peak detection also permits the incorporation of existing algorithms for peak detection in ion chromatograms and/or mass spectra. The application of these methods to LC/MS spectra of complex biological samples is described.
Copyright 2002 John Wiley & Sons, Ltd.
Similar articles
-
Optimized time alignment algorithm for LC-MS data: correlation optimized warping using component detection algorithm-selected mass chromatograms.Anal Chem. 2008 Sep 15;80(18):7012-21. doi: 10.1021/ac800920h. Epub 2008 Aug 21. Anal Chem. 2008. PMID: 18715018
-
An accurate-mass-based spectral-averaging isotope-pattern-filtering algorithm for extraction of drug metabolites possessing a distinct isotope pattern from LC-MS data.Anal Chem. 2009 Jul 15;81(14):5910-7. doi: 10.1021/ac900626d. Anal Chem. 2009. PMID: 19518135
-
An objective comparison of pre-processing methods for enhancement of liquid chromatography-mass spectrometry data.J Chromatogr A. 2007 Nov 23;1172(2):135-50. doi: 10.1016/j.chroma.2007.09.077. Epub 2007 Oct 10. J Chromatogr A. 2007. PMID: 17959187
-
System suitability in bioanalytical LC/MS/MS.J Pharm Biomed Anal. 2007 Jun 28;44(2):484-91. doi: 10.1016/j.jpba.2007.03.003. Epub 2007 Mar 13. J Pharm Biomed Anal. 2007. PMID: 17433601 Review.
-
Review, evaluation, and discussion of the challenges of missing value imputation for mass spectrometry-based label-free global proteomics.J Proteome Res. 2015 May 1;14(5):1993-2001. doi: 10.1021/pr501138h. Epub 2015 Apr 22. J Proteome Res. 2015. PMID: 25855118 Free PMC article. Review.
Cited by
-
A simple peak detection and label-free quantitation algorithm for chromatography-mass spectrometry.BMC Bioinformatics. 2014 Nov 25;15(1):376. doi: 10.1186/s12859-014-0376-0. BMC Bioinformatics. 2014. PMID: 25420746 Free PMC article.
-
MS1 ion current-based quantitative proteomics: A promising solution for reliable analysis of large biological cohorts.Mass Spectrom Rev. 2019 Nov;38(6):461-482. doi: 10.1002/mas.21595. Epub 2019 Mar 28. Mass Spectrom Rev. 2019. PMID: 30920002 Free PMC article. Review.
-
Hybrid feature detection and information accumulation using high-resolution LC-MS metabolomics data.J Proteome Res. 2013 Mar 1;12(3):1419-27. doi: 10.1021/pr301053d. Epub 2013 Feb 12. J Proteome Res. 2013. PMID: 23362826 Free PMC article.
-
Analyzing LC/MS metabolic profiling data in the context of existing metabolic networks.Curr Metabolomics. 2013 Jan 1;1(1):83-91. doi: 10.2174/2213235X11301010084. Curr Metabolomics. 2013. PMID: 24010053 Free PMC article.
-
Joint Bounding of Peaks Across Samples Improves Differential Analysis in Mass Spectrometry-Based Metabolomics.Anal Chem. 2017 Mar 21;89(6):3517-3523. doi: 10.1021/acs.analchem.6b04719. Epub 2017 Mar 7. Anal Chem. 2017. PMID: 28221771 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources