Automated deconvolution and deisotoping of electrospray mass spectra
- PMID: 11857767
- DOI: 10.1002/jms.278
Automated deconvolution and deisotoping of electrospray mass spectra
Abstract
Electrospray ionization (ESI) of peptides and proteins produces a series of multiply charged ions with a mass/charge (m/z) ratio between 500 and 2000. The resulting mass spectra are crowded by these multiple charge values for each molecular mass and an isotopic cluster for each nominal m/z value. Here, we report a new algorithm simultaneously to deconvolute and deisotope ESI mass spectra from complex peptide samples based on their mass-dependent isotopic mean pattern. All signals corresponding to one peptide in the sample were reduced to one singly charged monoisotopic peak, thereby significantly reducing the number of signals, increasing the signal intensity and improving the signal-to-noise ratio. The mass list produced could be used directly for database searching. The developed algorithm also simplified interpretation of fragment ion spectra of multiply charged parent ions.
Copyright 2002 John Wiley & Sons, Ltd.
Similar articles
-
Heuristic charge assignment for deconvolution of electrospray ionization mass spectra.Rapid Commun Mass Spectrom. 2003;17(5):429-36. doi: 10.1002/rcm.927. Rapid Commun Mass Spectrom. 2003. PMID: 12590391
-
Charge ratio analysis method: approach for the deconvolution of electrospray mass spectra.Anal Chem. 2005 Jan 1;77(1):111-9. doi: 10.1021/ac048961+. Anal Chem. 2005. PMID: 15623285
-
Characterization of cysteinylation of pharmaceutical-grade human serum albumin by electrospray ionization mass spectrometry and low-energy collision-induced dissociation tandem mass spectrometry.Rapid Commun Mass Spectrom. 2005;19(20):2965-73. doi: 10.1002/rcm.2154. Rapid Commun Mass Spectrom. 2005. PMID: 16178042
-
Recent developments in the ion/ion chemistry of high-mass multiply charged ions.Mass Spectrom Rev. 2005 Nov-Dec;24(6):931-58. doi: 10.1002/mas.20048. Mass Spectrom Rev. 2005. PMID: 15706594 Review.
-
Molecular weight determination of peptides and proteins by ESI and MALDI.Methods Enzymol. 2005;405:1-36. doi: 10.1016/S0076-6879(05)05001-9. Methods Enzymol. 2005. PMID: 16413308 Review.
Cited by
-
Increasing peptide identification in tandem mass spectrometry through automatic function switching optimization.J Am Soc Mass Spectrom. 2005 Nov;16(11):1818-26. doi: 10.1016/j.jasms.2005.07.022. Epub 2005 Sep 28. J Am Soc Mass Spectrom. 2005. PMID: 16198121
-
Quantifying Kinase-Specific Phosphorylation Stoichiometry Using Stable Isotope Labeling In a Reverse In-Gel Kinase Assay.Anal Chem. 2016 Dec 6;88(23):11468-11475. doi: 10.1021/acs.analchem.6b02599. Epub 2016 Nov 18. Anal Chem. 2016. PMID: 27808495 Free PMC article.
-
multiplierz: an extensible API based desktop environment for proteomics data analysis.BMC Bioinformatics. 2009 Oct 29;10:364. doi: 10.1186/1471-2105-10-364. BMC Bioinformatics. 2009. PMID: 19874609 Free PMC article.
-
Mass Spectrometry in Pharmacokinetic Studies of a Synthetic Compound for Spinal Cord Injury Treatment.Biomed Res Int. 2015;2015:169234. doi: 10.1155/2015/169234. Epub 2015 May 19. Biomed Res Int. 2015. PMID: 26090386 Free PMC article.
-
Deconvolution and database search of complex tandem mass spectra of intact proteins: a combinatorial approach.Mol Cell Proteomics. 2010 Dec;9(12):2772-82. doi: 10.1074/mcp.M110.002766. Epub 2010 Sep 20. Mol Cell Proteomics. 2010. PMID: 20855543 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources