Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Mar 1;18(4):295-307.
doi: 10.1089/088922202753472874.

Quantitative detection of increasing HIV type 1 antibodies after seroconversion: a simple assay for detecting recent HIV infection and estimating incidence

Affiliations

Quantitative detection of increasing HIV type 1 antibodies after seroconversion: a simple assay for detecting recent HIV infection and estimating incidence

Bharat S Parekh et al. AIDS Res Hum Retroviruses. .

Abstract

We have devised a simple enzyme immunoassay (EIA) that detects increasing levels of anti-HIV IgG after seroconversion and can be used for detecting recent HIV-1 infection. Use of a branched peptide that included gp41 immunodominant sequences from HIV-1 subtypes B, E, and D allowed similar detection of HIV-specific antibodies among various subtypes. Because of the competitive nature of the capture EIA, a gradual increase in the proportion of HIV-1-specific IgG in total IgG was observed for 2 years after seroconversion. This was in contrast to results obtained with the conventional EIA using the same antigen in solid phase, which plateaus soon after seroconversion. The assay was used to test 622 longitudinal specimens from 139 incident infections in the United States (subtype B) and in Thailand (subtypes B and E). The assay was also performed with an additional 8 M urea incubation step to assess the contribution of high-avidity antibodies. Normalized optical density (OD-n) was calculated (ODspecimen/ODcalibrator), using a calibrator specimen. An incremental analysis indicated that a cutoff of 1.0 OD-n and a seroconversion period of 160 days offered the best combination of sensitivity and specificity for classifying incident or long-term infections. The urea step increased the seroconversion period to 180 days with similar sensitivity and specificity. Separate analysis of B and E subtype specimens yielded the same optimal OD-n threshold and similar seroconversion periods. The assay was further validated in African specimens (subtypes A, C, and D) where the observed incidence was within 10% of the expected incidence. This assay should be useful for detecting recent HIV-1 infection and for estimating incidence among diverse HIV-1 subtypes worldwide.

PubMed Disclaimer

LinkOut - more resources