Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Mar;94(3):706-10; table of contents.
doi: 10.1097/00000539-200203000-00042.

Ultrasound guidance for the psoas compartment block: an imaging study

Affiliations

Ultrasound guidance for the psoas compartment block: an imaging study

Lukas Kirchmair et al. Anesth Analg. 2002 Mar.

Abstract

We conducted this study to develop an ultrasound-guided approach to the psoas compartment and to assess its feasibility and accuracy by means of computed tomography (CT). Two examiners performed ultrasound-guided approaches at three levels (L2-3, L3-4, and L4-5) on 10 embalmed cadavers, which were seated prone. After each needle had been advanced into the psoas compartment under ultrasound guidance, the positions of their tips were computed by using two coordinates (A and B). Subsequently, axial transverse CT scans were made to verify the ultrasound measurements by using the same coordinates. In total, 48 approaches were performed (Examiner 1, n = 20; Examiner 2, n = 28). CT revealed that 47 of 48 ultrasound-guided approaches were performed exactly. In 1 of 48 approaches (L3-4), the tip of the needle was located posterior to the psoas muscle. The median differences between ultrasound and CT coordinates were 0.3 plus minus 0.3 cm for A and 0.2 plus minus 0.3 for B. Kendall's coefficient of concordance was 0.9 (P < 0.001) between ultrasound and CT measurements for both coordinates. These results indicate that ultrasound enables exact needle placement, as proved by CT. We conclude that ultrasound guidance might be a useful adjunct to increase the safety and efficacy of the psoas compartment block at these levels.

Implications: We developed an ultrasound-guided approach to the psoas compartment at the levels L2-3, L3-4, and L4-5. Feasibility and accuracy were tested on embalmed cadavers and verified by means of computed tomography. Ultrasound guidance proved to be feasible and accurate for the performance of psoas compartment blocks.

PubMed Disclaimer

LinkOut - more resources