The optical design of intraocular lens implants
- PMID: 1187085
The optical design of intraocular lens implants
Abstract
Intraocular lens implants have been around for more than 25 years. On the verge of a major breakthrough to ever widening popularity, there is, however, a general lack of understanding of the pertinent optical principles. A critical comparison is made between this new method and conventional methods of correcting aphakia. From this it appears that the visual needs of the patient are a decisive factor in the selection of the method of correction. Moreover, the full potential of intraocular lens implants can only be realized by appropriate selection of the power of the implant in each situation. To this end, ultrasonic measurement of the ocular axial length is indispensable. The use of standard power lens implants is inadequate. Formulas are presented to make an eye emmetropic or to give it any refractive error. Guidelines are given for the use of these formulas. Two methods for obtaining equal image size in unilateral antiphakia are described.
Similar articles
-
Intraoperative optical refractive biometry for intraocular lens power estimation without axial length and keratometry measurements.J Cataract Refract Surg. 2005 Aug;31(8):1530-6. doi: 10.1016/j.jcrs.2005.01.035. J Cataract Refract Surg. 2005. PMID: 16129287 Clinical Trial.
-
Compensation of aniseikonia with toric intraocular lenses and spherocylindrical spectacles.Ophthalmic Physiol Opt. 2005 Jan;25(1):35-44. doi: 10.1111/j.1475-1313.2004.00243.x. Ophthalmic Physiol Opt. 2005. PMID: 15649181
-
The emmetropic and the iseikonic implant lens: computer calculation of the refractive power and its accuracy.Ophthalmologica. 1975;171(6):467-86. doi: 10.1159/000307571. Ophthalmologica. 1975. PMID: 1178154
-
Calculation of intraocular lens power: a review.Acta Ophthalmol Scand. 2007 Aug;85(5):472-85. doi: 10.1111/j.1600-0420.2007.00879.x. Epub 2007 Apr 2. Acta Ophthalmol Scand. 2007. PMID: 17403024 Review.
-
Prescription and management of contact lenses in patients with monocular visual impairment.Optometry. 2007 Dec;78(12):652-6. doi: 10.1016/j.optm.2007.02.022. Optometry. 2007. PMID: 18054135 Review.
Cited by
-
A New Intraocular Lens Power Formula Integrating an Artificial Intelligence-Powered Estimation for Effective Lens Position Based on Chinese Eyes.Transl Vis Sci Technol. 2024 Oct 1;13(10):40. doi: 10.1167/tvst.13.10.40. Transl Vis Sci Technol. 2024. PMID: 39476087 Free PMC article.
-
An ensemble-based approach for estimating personalized intraocular lens power.Sci Rep. 2021 Nov 25;11(1):22961. doi: 10.1038/s41598-021-02288-x. Sci Rep. 2021. PMID: 34824338 Free PMC article.
-
Optimization of biometry for best refractive outcome in cataract surgery.Indian J Ophthalmol. 2024 Jan 1;72(1):29-43. doi: 10.4103/IJO.IJO_1219_23. Epub 2023 Dec 22. Indian J Ophthalmol. 2024. PMID: 38131567 Free PMC article. Review.
-
The SRK regression formula in calculating the dioptric power of intraocular lenses.Br J Ophthalmol. 1984 Apr;68(4):235-7. doi: 10.1136/bjo.68.4.235. Br J Ophthalmol. 1984. PMID: 6704359 Free PMC article.
-
Hereditary retinitis pigmentosa: recent findings from electroretinography, fundus reflectometry, and psychophysics.Int Ophthalmol Clin. 1980 Spring;20(1):39-52. doi: 10.1007/BF00149254. Int Ophthalmol Clin. 1980. PMID: 6995379 Review. No abstract available.
Publication types
MeSH terms
LinkOut - more resources