Neural space integrity of the lower cervical spine: effect of normal range of motion
- PMID: 11884906
- DOI: 10.1097/00007632-200203150-00006
Neural space integrity of the lower cervical spine: effect of normal range of motion
Abstract
Study design: An experimental investigation of intervertebral foramen and spinal canal neural space integrity was performed throughout physiologic range of motion of the lower cervical spine in intact human cadaver specimens.
Objective: To investigate cervical positions that might place the neural tissues of the spine in heightened risk of injury. To meet this objective the following hypotheses were tested: 1) spinal canal integrity varies with specific normal range of motion positions of the lower cervical spine, and 2) intervertebral foramen integrity is dependent on and unique for different physiologic positions of the lower cervical spine.
Summary of background data: Cervical spine injuries are frequently associated with compressive damage to neurologic tissues and consequently poor clinical outcomes. Neurologic injury typically occurs from disc, ligamentous, or bony occlusion of the spinal canal and intervertebral foraminal spaces dynamically during an injury event or with abnormal alignment and position after the injury event. Prior studies have shown pressure and geometric changes in cervical spine neural spaces in certain cervical spine positions. However, to the authors' knowledge, this is the first research effort aimed at elucidating the integrity of the cervical spine neural spaces throughout the normal physiologic range of motion.
Methods: The authors instrumented 17 fresh-frozen unembalmed cadaveric human cervical spines (C3-C7) with specially designed intervertebral foramen occlusion transducers and a spinal canal occlusion transducer. The specimens were loaded with pure bending moments to produce simulated physiologic motions of the lower cervical spine. The resulting occlusion profiles for the intervertebral foramen and spinal canal were recorded along with the 6-degree of freedom position of the cervical spine. Because these occlusion measurements describe the ability of the spine to preserve the space for the neural structures, the authors define this neuroprotective role of the vertebral column as neural space integrity.
Results: The range of motion developed experimentally in this study compared well with published reports of normal cervical motion. Thus, subsequent changes in neural space integrity may be regarded as resulting from normal human cervical spine motion. No significant change in the spinal canal space was detected for any physiologic motion; however, intervertebral foramen integrity was significantly altered in extension, ipsilateral bending, combined ipsilateral bending and extension, and combined contralateral bending with extension when compared with intact upright neutral position.
Conclusions: This study defines the range of neural space integrity associated with simulated physiologic motion of the lower cervical spine in an experimental setting. This information may be useful in comparing neural space changes in pathologic conditions and may enhance refinement of neurologic injury prevention strategies.
Similar articles
-
Neural space integrity of the lower cervical spine: effect of anterior lesions.Spine (Phila Pa 1976). 2004 Mar 15;29(6):642-9. doi: 10.1097/01.brs.0000115132.49734.33. Spine (Phila Pa 1976). 2004. PMID: 15014274
-
Anatomic changes of the spinal canal and intervertebral foramen associated with flexion-extension movement.Spine (Phila Pa 1976). 1996 Nov 1;21(21):2412-20. doi: 10.1097/00007632-199611010-00002. Spine (Phila Pa 1976). 1996. PMID: 8923625
-
The effect of post-injury spinal position on canal occlusion in a cervical spine burst fracture model.Spine (Phila Pa 1976). 1997 Aug 1;22(15):1710-5. doi: 10.1097/00007632-199708010-00005. Spine (Phila Pa 1976). 1997. PMID: 9259780
-
Biomechanics of the cervical spine. I: Normal kinematics.Clin Biomech (Bristol). 2000 Nov;15(9):633-48. doi: 10.1016/s0268-0033(00)00034-6. Clin Biomech (Bristol). 2000. PMID: 10946096 Review.
-
The Differences Among Kinematic Parameters for Evaluating the Quality of Intervertebral Motion of the Cervical Spine in Clinical and Experimental Studies: Concepts, Research and Measurement Techniques. A Literature Review.World Neurosurg. 2020 Jan;133:343-357.e1. doi: 10.1016/j.wneu.2019.09.075. Epub 2019 Sep 21. World Neurosurg. 2020. PMID: 31550538 Review.
Cited by
-
Spinal canal narrowing during simulated frontal impact.Eur Spine J. 2006 Jun;15(6):891-901. doi: 10.1007/s00586-005-0985-4. Epub 2005 Oct 12. Eur Spine J. 2006. PMID: 16220351 Free PMC article.
-
Measurement of volume-occupying rate of cervical spinal canal and its role in cervical spondylotic myelopathy.Eur Spine J. 2013 May;22(5):1152-7. doi: 10.1007/s00586-012-2622-3. Epub 2013 Jan 6. Eur Spine J. 2013. PMID: 23291855 Free PMC article.
-
Cervical radiculopathy: study protocol of a randomised clinical trial evaluating the effect of mobilisations and exercises targeting the opening of intervertebral foramen [NCT01500044].BMC Musculoskelet Disord. 2012 Jan 31;13:10. doi: 10.1186/1471-2474-13-10. BMC Musculoskelet Disord. 2012. PMID: 22293092 Free PMC article. Clinical Trial.
-
Dynamic foraminal dimensions during neck motion 6.5 years after fusion and artificial disc replacement.PLoS One. 2020 Aug 11;15(8):e0237350. doi: 10.1371/journal.pone.0237350. eCollection 2020. PLoS One. 2020. PMID: 32780779 Free PMC article.
-
Cervical neural space narrowing during simulated rear crashes with anti-whiplash systems.Eur Spine J. 2012 May;21(5):879-86. doi: 10.1007/s00586-012-2159-5. Epub 2012 Jan 24. Eur Spine J. 2012. PMID: 22270248 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous