Effect of electrocardiographic filters on the R-amplitude of canine electrocardiograms
- PMID: 11888110
- DOI: 10.1136/vr.150.6.171
Effect of electrocardiographic filters on the R-amplitude of canine electrocardiograms
Abstract
Lead II electrocardiograms (ECGs) were recorded in 88 dogs ranging in weight from 3 to 50 kg. A commercial direct-writing electrocardiograph was used to record the ECGs, first with manual HUM filter (notch filter at 50/60 Hz) and EMG filter (cut-off frequency of -3 dB at 35 Hz) on, immediately followed by a recording with both filters off. The mean (sd) reduction in R-amplitude with the filters on was 53(18) per cent with a range from 22 to 100 per cent and a median value of 51 per cent. The R-amplitude with the filters off was related to the R-amplitude with the filters on, making it possible to correct for the effect of the filters. The reduction in R-amplitude was inversely correlated with the weight of the dog and with the duration of the QRS-complex. Other known changes induced by filters, such as the elimination of notches and the slurring of the junction between the QRS-complex and the ST-interval were also observed. The inverse relationship between the weight of the dog and the magnitude of the reduction in R-amplitude by the filters indicates that ECG machines with different characteristics should ideally be used to record ECGs in dogs of different sizes.
Similar articles
-
Effects of electrocardiograph frequency filters on P-QRS-T amplitudes of the feline electrocardiogram.Am J Vet Res. 1995 Nov;56(11):1534-40. Am J Vet Res. 1995. PMID: 8585669
-
Online digital filter and QRS detector applicable in low resource ECG monitoring systems.Ann Biomed Eng. 2008 Nov;36(11):1805-15. doi: 10.1007/s10439-008-9553-5. Epub 2008 Aug 28. Ann Biomed Eng. 2008. PMID: 18752068
-
Minimum bandwidth requirements for recording of pediatric electrocardiograms.Circulation. 2001 Dec 18;104(25):3087-90. doi: 10.1161/hc5001.101063. Circulation. 2001. PMID: 11748105
-
Digital DC-Reconstruction of AC-Coupled Electrophysiological Signals with a Single Inverting Filter.PLoS One. 2016 Mar 3;11(3):e0150207. doi: 10.1371/journal.pone.0150207. eCollection 2016. PLoS One. 2016. PMID: 26938769 Free PMC article.
-
What is inside the electrocardiograph?J Electrocardiol. 2008 Jan-Feb;41(1):8-14. doi: 10.1016/j.jelectrocard.2007.08.059. J Electrocardiol. 2008. PMID: 18191652 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous