Comparative Study
. 2002 Jan;42(1):87-93.
doi: 10.1046/j.1537-2995.2002.00009.x.

Quantitation of residual WBCs in filtered blood components by high-throughput, real-time kinetic PCR

Affiliations
Comparative Study

Quantitation of residual WBCs in filtered blood components by high-throughput, real-time kinetic PCR

Tzong-Hae Lee et al. Transfusion. 2002 Jan.

Abstract

Background: The effort to eliminate transfusion complications associated with WBCs has led to the widespread use of filters able to reduce WBC concentrations to <or=0.1 WBC per microL blood. This has necessitated sensitive QC methods to quantitate residual WBCs in filtered units. One fast, effective method is DNA amplification using real-time kinetic PCR (kPCR).

Study design and methods: Two methods of preparation of standards were compared and used for the optimization of quantitative kPCR. The first involved spiking genomic DNA cell lysate into a diluent, followed by a series of 1 in 10 dilutions. The second involved spiking serial 1 in 10 dilutions of WBCs into twice-filtered fresh whole blood. Two hundred fifty filtered frozen whole-blood samples were amplified in duplicate to show the kPCR assay's reproducibility. Another 359 filtered frozen whole blood samples were used to compare data from kPCR with data from a standard PCR protocol using (32)P-labeled probe and autoradiography. All specimens were amplified for conserved HLA DQ(alpha) sequences.

Results: Standards prepared by both methods gave reproducible and equivalent results. Quantitation of standards representing a dynamic range of 8 x 10(o) to 8 x 10(5) WBCs per mL, yielded standard deviations ranging from 0.59 cycle to 1.04 cycles (a one-cycle increase is equivalent to a twofold increase in WBC concentration). The scatter graph of the 250 samples tested in duplicate by kPCR generated a slope of 1.0122 and an R(2) value of 0.9265. The comparison of kPCR and (32)P-probe hybridization results on 359 clinical samples gave a scatter-graph slope of 0.9428 and an R(2) value of 0.8718, indicating excellent agreement of the methods over a 4-log dynamic range.

Conclusion: kPCR is a high-throughput, sensitive assay that could prove useful in routine quality assurance of the WBC reduction process.