Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2002 Mar;109(3):410-8.
doi: 10.1067/mai.2002.122635.

Significant variability in response to inhaled corticosteroids for persistent asthma

Affiliations
Clinical Trial

Significant variability in response to inhaled corticosteroids for persistent asthma

Stanley J Szefler et al. J Allergy Clin Immunol. 2002 Mar.

Abstract

Background: A clinical model is needed to compare inhaled corticosteroids (ICSs) with respect to efficacy.

Objective: The purpose of this investigation was to compare the relative beneficial and systemic effects in a dose-response relationship for 2 ICSs.

Methods: A 24-week, parallel, open-label, multicenter trial examined the benefit-risk ratio of 2 ICSs in persistent asthma. Benefit was assessed by improvements in FEV(1) and PC(20); risk was assessed by overnight plasma cortisol suppression. Thirty subjects were randomized to either beclomethasone dipropionate (BDP) 168, 672, and 1344 microg/day (n = 15) or fluticasone propionate (FP) 88, 352, and 704 microg/day (n = 15), both administered by means of a metered dose inhaler (MDI) with chlorofluorocarbon propellant via a spacer, in 3 consecutive 6-week intervals; this was followed by 3 weeks of FP dry powder inhaler (DPI) 2000 microg/day.

Results: Maximum FEV(1) response occurred with the low dose for FP-MDI and the medium dose for BDP-MDI and was not further increased by treatment with FP-DPI. Near-maximum methacholine PC(20) improvement occurred with the low dose for FP-MDI and the medium dose for BDP-MDI. Both BDP-MDI and FP-MDI caused dose-dependent cortisol suppression. Responsiveness to ICS treatment was found to vary markedly among subjects. Good (>15%) FEV(1) response, in contrast to poor (<5%) response, was found to be associated with high exhaled nitric oxide (median, 17.6 vs 11.1 ppb), high bronchodilator reversibility (25.2% vs 8.8%), and a low FEV(1)/forced vital capacity ratio (0.63 vs 0.73) before treatment. Excellent (>3 doubling dilutions) improvement in PC(20), in contrast to poor (<1 doubling dilution) improvement, was found to be associated with high sputum eosinophil levels (3.4% vs 0.1%) and older age at onset of asthma (age, 20-29 years vs <10 years).

Conclusions: Near-maximal FEV(1) and PC(20) effects occurred with low-medium dose for both ICSs in the subjects studied. High-dose ICS therapy did not significantly increase the efficacy measures that were evaluated, but it did increase the systemic effect measure, overnight cortisol secretion. Significant intersubject variability in response occurred with both ICSs. It is possible that higher doses of ICSs are necessary to manage more severe patients or to achieve goals of therapy not evaluated in this study, such as prevention of asthma exacerbations.

PubMed Disclaimer

Comment in

  • Defining the responder in asthma therapy.
    Stempel DA, Fuhlbrigge AL. Stempel DA, et al. J Allergy Clin Immunol. 2005 Mar;115(3):466-9. doi: 10.1016/j.jaci.2004.12.1113. J Allergy Clin Immunol. 2005. PMID: 15753889 Review. No abstract available.

Publication types

MeSH terms