[Comparison between fast MR flow quantification in breathhold technique in ascending aorta and pulmonary trunc with right and left ventricular cine-MRI for the assessment of stroke volumes in healthy volunteers]
- PMID: 11898082
- DOI: 10.1055/s-2002-20104
[Comparison between fast MR flow quantification in breathhold technique in ascending aorta and pulmonary trunc with right and left ventricular cine-MRI for the assessment of stroke volumes in healthy volunteers]
Abstract
Purpose: Evaluation of accordance and reproducibility of the stroke volume assessment of fast flow measurement in breathhold technique in the ascending aorta and pulmonary trunc with fast right (RV) and left ventricular (LV) cine-MRI.
Material and methods: The correlation an accordance of stroke volumes (SV) were evaluated by flow measurements in the ascending aorta and pulmonary trunc and RV and LV volumetric cine-MRI in 33 cardiac healthy volunteers. Interobserver and intraobserver variability of the different measurement methods and locations were checked in 10 cardiac healthy volunteers.
Results: With respect to the early systolic flow and the extrapolation of the endiastolic flow rate the difference in SV was smaller than 1,5 ml/m(2) for all possible combinations. The interobserver and intraobserver variabilities of flow measurements were significantly lower by approximately a factor of 2.5 than those of RV and LV cine-MRI.
Conclusion: The accordance of fast prospective triggered flow measurements in the ascending aorta and pulmonary trunc with RV and LV cine-MRI can be achieved with reasonable limits of agreement. Flow measurements are more reproducible than cine-MRI.
Similar articles
-
[Comparison between biventricular cine MRI and MR flow quantification in ascending aorta and pulmonary outflow tract for the assessment of intracardial shunt volumes].Rofo. 2002 Nov;174(11):1380-6. doi: 10.1055/s-2002-35336. Rofo. 2002. PMID: 12424664 German.
-
[Biventricular MR volumetric analysis and MR flow quantification in the ascending aorta and pulmonary trunk for quantification of valvular regurgitation].Rofo. 2004 Mar;176(3):342-9. doi: 10.1055/s-2004-812751. Rofo. 2004. PMID: 15026947 German.
-
[Accuracy of right and left ventricular heart volume and left ventricular muscle mass determination with cine MRI in breath holding technique].Rofo. 1999 Jan;170(1):54-60. doi: 10.1055/s-2007-1011007. Rofo. 1999. PMID: 10071645 German.
-
Right ventricular function by MRI.Curr Opin Cardiol. 2010 Sep;25(5):451-5. doi: 10.1097/HCO.0b013e32833b78e6. Curr Opin Cardiol. 2010. PMID: 20543681 Review.
-
Cardiovascular applications of magnetic resonance flow measurement.Rays. 2001 Jan-Mar;26(1):71-91. Rays. 2001. PMID: 11471350 Review.
Cited by
-
Assessment of lung function in children by cross-sectional imaging: techniques and clinical applications.Pediatr Radiol. 2006 Mar;36(3):192-204, quiz 280-1. doi: 10.1007/s00247-005-0027-8. Epub 2005 Nov 15. Pediatr Radiol. 2006. PMID: 16292526 Review.
-
Proton MRI appearance of cystic fibrosis: comparison to CT.Eur Radiol. 2007 Mar;17(3):716-24. doi: 10.1007/s00330-006-0373-4. Epub 2006 Aug 29. Eur Radiol. 2007. PMID: 16941092
-
Cardiac index after acute ST-segment elevation myocardial infarction measured with phase-contrast cardiac magnetic resonance imaging.Eur Radiol. 2016 Jul;26(7):1999-2008. doi: 10.1007/s00330-015-4022-7. Epub 2015 Sep 18. Eur Radiol. 2016. PMID: 26385805
-
[MRI in mucoviscidosis (cystic fibrosis)].Radiologe. 2006 Apr;46(4):275-6, 278-81. doi: 10.1007/s00117-005-1308-9. Radiologe. 2006. PMID: 16437239 Review. German.
-
Assessment of pulmonary hypertension by CT and MR imaging.Eur Radiol. 2004 Mar;14(3):359-68. doi: 10.1007/s00330-003-2208-x. Epub 2004 Jan 23. Eur Radiol. 2004. PMID: 14740163 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical