Outpatient phlebotomy success and reasons for specimen rejection
- PMID: 11900564
- DOI: 10.5858/2002-126-0416-OPSARF
Outpatient phlebotomy success and reasons for specimen rejection
Abstract
Objectives: To determine the rate with which blood collection is successful on the initial phlebotomy encounter, the rate with which laboratory personnel judge specimens unsuitable for analysis, and the practice characteristics associated with fewer unsuccessful collections and fewer rejected specimens.
Design: Clinical laboratories participating in the College of American Pathologists Q-Probes laboratory improvement program prospectively characterized the outcome of outpatient phlebotomies for 3 months or until 20 unsuccessful phlebotomy encounters occurred. By questionnaire, participants provided information about test ordering, patient preparation, and specimen collection.
Setting and participants: Institutions in the United States (n = 202), Canada (n = 4), Australia (n = 3), and South Korea (n = 1).
Main outcome measures: Percentage of successful encounters and percentage of unsuitable specimens.
Results: Of 833289 encounters, 829723 were successful. Phlebotomies were unsuccessful because patients were not fasting as directed (32.2%), phlebotomy orders were missing information (22.5%), patients specimens were difficult to draw (13.0%), patients left the collection area before specimens were collected (11.8%), patients were improperly prepared for reasons other than fasting (6.3%), patients presented at the wrong time (3.1%), or for other reasons (11.8%). Only 2153 specimens (0.3%) were unsuitable; these samples were hemolyzed (18.1%), of insufficient quantity (16.0%), clotted (13.4%), lost or not received in the laboratory (11.5%), inadequately labeled (5.8%), at variance with previous or expected results (4.8%), or unacceptable for other reasons (31.1%). Facilities staffed by laboratory-administered phlebotomists reported higher success rates than facilities staffed by nonlaboratory-administered phlebotomists (P =.002).
Conclusions: Most outpatient phlebotomy encounters are successful and result in specimens suitable for laboratory analysis.
Similar articles
-
Chemistry specimen acceptability: a College of American Pathologists Q-Probes study of 453 laboratories.Arch Pathol Lab Med. 1997 Jan;121(1):19-26. Arch Pathol Lab Med. 1997. PMID: 9111088
-
Complete blood count specimen acceptability. A College of American Pathologists Q-Probes study of 703 laboratories.Arch Pathol Lab Med. 1995 Mar;119(3):203-8. Arch Pathol Lab Med. 1995. PMID: 7887772
-
Specimen labeling errors: a Q-probes analysis of 147 clinical laboratories.Arch Pathol Lab Med. 2008 Oct;132(10):1617-22. doi: 10.5858/2008-132-1617-SLEAQA. Arch Pathol Lab Med. 2008. PMID: 18834220
-
Pre-analytical phase management: a review of the procedures from patient preparation to laboratory analysis.Scand J Clin Lab Invest. 2017 May;77(3):153-163. doi: 10.1080/00365513.2017.1295317. Epub 2017 Mar 7. Scand J Clin Lab Invest. 2017. PMID: 28266238 Review.
-
Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories.Crit Rev Clin Lab Sci. 2011 May-Jun;48(3):143-53. doi: 10.3109/10408363.2011.600228. Crit Rev Clin Lab Sci. 2011. PMID: 21875312 Review.
Cited by
-
Role of intervention on laboratory performance: evaluation of quality indicators in a tertiary care hospital.Indian J Clin Biochem. 2012 Jan;27(1):61-8. doi: 10.1007/s12291-011-0182-7. Epub 2012 Jan 7. Indian J Clin Biochem. 2012. PMID: 23277714 Free PMC article.
-
Effectiveness of Laboratory Practices to Reducing Patient Misidentification Due to Specimen Labeling Errors at the Time of Specimen Collection in Healthcare Settings: LMBP™ Systematic Review.J Appl Lab Med. 2017 Sep;2(2):244-258. doi: 10.1373/jalm.2017.023762. J Appl Lab Med. 2017. PMID: 29181454 Free PMC article.
-
The Evaluation of Error Types and Turnaround Time of Preanalytical Phase in Biochemistry and Hematology Laboratories.Iran J Pathol. 2018 Spring;13(2):173-178. Epub 2018 Jul 17. Iran J Pathol. 2018. PMID: 30697287 Free PMC article.
-
Customer satisfaction survey with clinical laboratory and phlebotomy services at a tertiary care unit level.Ann Lab Med. 2014 Sep;34(5):380-5. doi: 10.3343/alm.2014.34.5.380. Epub 2014 Aug 21. Ann Lab Med. 2014. PMID: 25187892 Free PMC article.
-
Three years' experience of quality monitoring program on pre-analytical errors in china.J Clin Lab Anal. 2021 Mar;35(3):e23699. doi: 10.1002/jcla.23699. Epub 2021 Jan 17. J Clin Lab Anal. 2021. PMID: 33458892 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources