Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1975 Oct;8(4):429-33.
doi: 10.1128/AAC.8.4.429.

Relationship of early readings of minimal inhibitory concentrations to the results of overnight tests

Relationship of early readings of minimal inhibitory concentrations to the results of overnight tests

M F Lampe et al. Antimicrob Agents Chemother. 1975 Oct.

Abstract

Broth dilution minimal inhibitory concentration (MIC) readings were compared after different incubation periods and with different inoculum concentrations. The purpose was to determine the best conditions for obtaining early results as close as possible to overnight readings. Initially, 76 antibiotic-organism combinations were tested using the International Collaborative Study technique and inoculum and were read after 3, 8, and 18 h of incubation. Approximately 28% of tests showed fourfold or greater increases in MICs after 18 h of incubation compared with the 3-h readings. No overnight MICs were lower than early readings. MICs of single antibiotics against seven organisms were also read with an automatic particle counter to confirm the validity of the visual readings. Experiments were made to determine whether inoculum manipulation could reconcile the differences between 3- and 18-h MIC results. One hundred and eight organism-antibiotic combinations were tested comparing 3-h MIC readings using an inoculum of 10(7) organisms per ml with overnight readings using 10(5) per ml. In 71 cases, readings with both inocula were within the range tested and 57 (86%) were within +/-1 log(2) of each other and followed an approximately normal distribution. Improved comparability between early read and overnight MICs thus may be achieved by inoculum manipulation, and this may be a suitable approach in the future development of automated procedures.

PubMed Disclaimer

References

    1. J Bacteriol. 1964 Apr;87:887-99 - PubMed
    1. Am J Clin Pathol. 1951 Sep;21(9):884-91 - PubMed
    1. AMA Arch Intern Med. 1951 Oct;88(4):446-60 - PubMed
    1. Acta Pathol Microbiol Scand Suppl. 1951;85:1-162 - PubMed
    1. Antimicrob Agents Chemother. 1975 Apr;7(4):466-80 - PubMed

MeSH terms

Substances

LinkOut - more resources