Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Mar;19(3):195-200.
doi: 10.1046/j.1464-5491.2002.00601.x.

Assessing diabetic control--reliability of methods available in resource poor settings

Affiliations

Assessing diabetic control--reliability of methods available in resource poor settings

A P Rotchford et al. Diabet Med. 2002 Mar.

Abstract

Aims and methods: To examine the reliability of random venous or capillary blood glucose testing, random urine glucose testing, and a current symptom history in predicting a high HbA1c in Type 2 diabetic patients taking oral hypoglycaemic agents in a poorly controlled rural African population.

Results: For a cut-off point for HbA1c of > or = 8%, for random venous plasma glucose of > or = 14 mmol/L (present in 47.2% of subjects), specificity was 97.1% (95% CI 85.1-99.9), sensitivity 56.8% (48.8-64.5) and positive predictive value (PPV) 98.9% (94.2-99.9). HbA1c > or = 8% is predicted by a random capillary blood glucose of 17 mmol/L (present in 28.4% of subjects) with specificity 100% (90.0-100.0), PPV 100% (93.7-100.0) and sensitivity of 34.3% (27.2-42.1). HbA1c > or = 8% is predicted by the presence of heavy glycosuria (> or = 55 mmol/L) (present in 35.6%) with specificity 94.1% (80.3-99.3), sensitivity of 41.9% (34.1-49.9) and PPV 97.1% (89.9-99.6). Polyuria/nocturia (present in 31.3%) was the only symptom found to be associated with poor control, with a specificity for predicting HbA1c of > or = 8% of 81.5% (61.9-93.7), PPV 89.1% (76.4-96.4) and sensitivity 30.6% (22.9-39.1).

Conclusions: Where resources are short, random glucose testing can be used to detect a significant proportion of those with the worst control with a high degree of specificity enabling primary care staff to modify treatment safely. Where facilities are limited capillary blood or urine testing with reagent strips, may be substituted for venous plasma testing in the laboratory. A symptom history was insufficient to replace biochemical testing, but where this is unavailable, urinary symptoms may be helpful.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources