Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2002 Feb 1;105(3):241-6.
doi: 10.1016/s0049-3848(02)00023-3.

Markers of hemostatic system activation during treatment of deep vein thrombosis with subcutaneous unfractionated or low-molecular weight heparin

Affiliations
Clinical Trial

Markers of hemostatic system activation during treatment of deep vein thrombosis with subcutaneous unfractionated or low-molecular weight heparin

Polona Peternel et al. Thromb Res. .

Abstract

Prothrombin fragments (F1+2), thrombin-antithrombin complexes (TAT) and D-dimers, markers of hemostatic system activation, were measured in 59 consecutive patients with deep vein thrombosis (DVT). Patients were randomly treated either with subcutaneous unfractionated heparin (UH) administered in two to three subcutaneous doses adjusted to activated partial thromboplastin time (APTT) or with low-molecular weight heparin (LMWH) (dalteparin) administered in a fixed dose of 200 IU/kg body weight in one subcutaneous injection daily. Before treatment, F1+2, TAT and D-dimer were above the cut-off level in 27/59 (46%), 34/59 (58%) and all (100%) patients, respectively. Significant associations were observed between F1+2 and TAT (r=.66, P<.001), TAT and D-dimer (r=.36, P<.005) and F1+2 and D-dimer (r=.30, P<.050). On the third day of treatment, F1+2 and TAT significantly decreased to reference values in almost all patients (in 64/66 determinations of both F1+2 and TAT) and remained low on the seventh day of treatment. Compared to pretreatment values, a nonsignificant decrease of D-dimer was noted in both groups, but all values remained above the cut-off value. When markers of hemostatic system activation in the UH and LMWH groups were compared, no significant differences were observed. It was concluded that subcutaneous UH in an APTT-adjusted dose and subcutaneous LMWH in a once-daily weight-adjusted dose controlled these markers of hemostatic system activation in a similar manner.

PubMed Disclaimer

Publication types

LinkOut - more resources