Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Apr;14(4):409-12.
doi: 10.1097/00042737-200204000-00013.

A new, highly sensitive assay for C-reactive protein can aid the differentiation of inflammatory bowel disorders from constipation- and diarrhoea-predominant functional bowel disorders

Affiliations

A new, highly sensitive assay for C-reactive protein can aid the differentiation of inflammatory bowel disorders from constipation- and diarrhoea-predominant functional bowel disorders

Andrew P Poullis et al. Eur J Gastroenterol Hepatol. 2002 Apr.

Abstract

Background: Patients presenting to gastroenterology clinics with symptoms suggestive of lower-bowel disorders often require extensive investigation to differentiate functional from organic disease. C-reactive protein (CRP) is a sensitive marker of systemic inflammation. Levels of CRP are frequently raised in cases of inflammatory bowel disease (IBD). However, using conventional assays, not all cases of IBD have a detectable level.

Objective: To determine whether a new highly sensitive CRP enzyme-linked immunosorbent assay (ELISA) can aid the differentiation between IBD and functional bowel disorders (FBDs) in gastroenterology outpatients presenting with lower-bowel symptoms.

Methods: Serum was taken from 224 subjects attending a gastroenterology outpatient clinic. Of these, 203 were new patients and 21 were follow-up patients with quiescent colitis. The serum was analysed using a sensitive in-house ELISA. All new patients had a rigid sigmoidoscopy and rectal biopsy. Patients were investigated as deemed appropriate by the attending physician. Notes were reviewed after at least 6 months to determine the final diagnosis.

Results: A cut-off value of 2.3 mg/l had a sensitivity of 100% and a specificity of 67% in differentiating FBD from new cases of IBD. The geometric mean CRP was 0.383 mg/l in the constipation-predominant FBD group, 1.435 mg/l in diarrhoea-predominant FBD, 1.455 mg/l in quiescent IBD, 8.892 mg/l in newly presenting cases of ulcerative colitis, and 13.123 mg/l in newly presenting cases of Crohn's disease.

Conclusion: A new, highly sensitive assay for CRP may help to distinguish FBD from IBD.

PubMed Disclaimer

Publication types

Substances