Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2002 Mar;140(3):315-20.
doi: 10.1067/mpd.2002.122470.

Indwelling catheters used from the onset of diabetes decrease injection pain and pre-injection anxiety

Affiliations
Clinical Trial

Indwelling catheters used from the onset of diabetes decrease injection pain and pre-injection anxiety

Ragnar Hanas et al. J Pediatr. 2002 Mar.

Erratum in

  • J Pediatr 2002 Aug;141(2):298. Jansson, Iner [corrected to Jansson, Inger]; Wilk, Annica [corrected to Wiik, Annica]

Abstract

Objectives: To investigate the use of indwelling catheters as injection aids at diabetes onset to reduce injection pain and pre-injection anxiety.

Study design: Forty-one patients aged 8.1 +/- 3.7 years (range, 1-15) participated in this open, controlled randomized study. A 10-cm VAS with faces was used for scoring. A local anesthetic cream was used before all insertions. The control group used insulin pens with standard needles. After one week, the indwelling catheter group could choose regular injections but were included in the "intention to treat" analysis.

Results: Injection pain and anxiety decreased from day 1 to 15 in both groups (average, 4.1 injections/day). Pain was significantly lower for indwelling catheter injections when scored by parents (median, 1.2 cm vs 2.7 cm; P =.002), children/teenagers (0.8 cm vs 1.5 cm; P =.006), and nurses (1.4 cm vs 3.0 cm; P =.002). Parental pre-injection anxiety was also lower (1.2 cm vs 2.9 cm; P =.016). Taking injections, including inserting catheters, was found to be less problematic with an indwelling catheter (1.6 cm vs 3.3 cm;P =.009). During the 6-month follow-up, injection pain and injection problems were significantly lower in the catheter group. Mean catheter indwelling time was 3.7 days. Median pain for catheter insertion was 2.1 cm and for glucose testing was 0.9 cm. Sixteen of 20 patients continued to use indwelling catheters after 2 weeks, and 9 of 20 after 6 months.

Conclusions: We found an evident relief of pre-injection anxiety and injection pain when using indwelling catheters for introducing insulin injections at the onset of diabetes.

PubMed Disclaimer

Publication types

MeSH terms