Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2002 May;22(5):605-11.
doi: 10.1097/00004647-200205000-00012.

Comparison of near-infrared spectroscopy and tissue p(O2) time series in patients after severe head injury and aneurysmal subarachnoid hemorrhage

Affiliations
Comparative Study

Comparison of near-infrared spectroscopy and tissue p(O2) time series in patients after severe head injury and aneurysmal subarachnoid hemorrhage

Alexander Brawanski et al. J Cereb Blood Flow Metab. 2002 May.

Abstract

Monitoring of local oxygen pressure in brain white matter (tip(O2)) and of local hemoglobin oxygen saturation (rS(O2)) with near-infrared spectroscopy (NIRS) are increasingly employed techniques in neurosurgical intensive care units. Using frequency-based mathematical methods, the authors sought to ascertain whether both techniques contained similar information. Twelve patients treated in the intensive care unit were included (subarachnoid hemorrhage, n = 3; traumatic brain injury, n = 9). A tip(O2) probe and an NIRS sensor were positioned over the frontal lobe with the most pathologic changes on initial computed tomography scan. The authors calculated coherence of tip(O2) and rS(O2) ts overall density distribution, its distribution per data set, and its time evolution. The authors identified a band of significantly correlated frequencies (from 0 to 1.3 x 10(3) Hz) in more than 90% of the data sets for coherence and overall density distribution. Time evolution showed slow but marked changes of significant coherence. By means of spectral analysis the authors show that tip(O2) and rS(O2)signals contain similar information, albeit using completely different registration methodologies.

PubMed Disclaimer

Publication types

LinkOut - more resources