Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2002 Apr;96(3 Suppl):277-84.
doi: 10.3171/spi.2002.96.3.0277.

Cervical nerve root avulsion in brachial plexus injuries: magnetic resonance imaging classification and comparison with myelography and computerized tomography myelography

Affiliations
Comparative Study

Cervical nerve root avulsion in brachial plexus injuries: magnetic resonance imaging classification and comparison with myelography and computerized tomography myelography

Kazuteru Doi et al. J Neurosurg. 2002 Apr.

Abstract

Object: The authors describe a new magnetic resonance (MR) imaging technique to demonstrate the status of the cervical nerve roots involved in brachial plexus injury. They discuss the accuracy and reproducibility of a MR imaging-derived classification for diagnosis of nerve root avulsion compared with those of myelography combined with computerized tomography (CT) myelography.

Methods: The overlapping coronal-oblique slice MR imaging procedure was performed in 35 patients with traumatic brachial plexus injury and 10 healthy individuals. The results were retrospectively evaluated and classified into four major categories (normal rootlet, rootlet injuries, avulsion, and meningocele) after confirming the diagnosis by surgical exploration with or without spinal evoked potential (EP) measurements and by referring to myelography and CT myelography findings. The reliability and reproducibility of the MR imaging-based classification was prospectively assessed by eight independent observers, and its diagnostic accuracy was compared with that of traditional myelography/CT myelography classification, correlated with surgical and spinal EP findings in another 50 cervical roots in 10 patients with traumatic brachial plexus injury.

Conclusions: In the retrospective study in which MR imaging and myelography/CT myelography findings involving 175 cervical roots in 35 patients were compared, the sensitivity of detection of the cervical nerve root avulsion was the same (92.9%) with both modalities. In the prospective study, interobserver reliability and intraobserver reproducibility showed that there was no statistically significant difference between MR imaging and myelography/CT myelography and that their accuracy for detecting cervical root avulsion was the same as that in the retrospective study. The overlapping coronal-oblique slice MR imaging technique is a reliable and reproducible method for detecting nerve root avulsion. The information provided by this modality enabled the authors to assess the roots of the brachial plexus and provided valuable data for helping to decide whether to proceed with exploration, nerve repair, primary reconstruction, or other imaging modalities.

PubMed Disclaimer

Publication types

MeSH terms