Comparative study on collagen-binding enzyme-linked immunosorbent assay and ristocetin cofactor activity assays for detection of functional activity of von Willebrand factor
- PMID: 11992238
- DOI: 10.1055/s-2002-27817
Comparative study on collagen-binding enzyme-linked immunosorbent assay and ristocetin cofactor activity assays for detection of functional activity of von Willebrand factor
Abstract
For more than two decades, the ristocetin cofactor (RCo) assay, which measures the von Willebrand factor (vWF)-mediated agglutination of platelets in the presence of the antibiotic ristocetin, has been the most common method for measuring the functional activity of vWF. There is, however, general agreement among clinical analysts that this method has major practical disadvantages in performance and reproducibility. Today, collagen-binding assays (CBA) based on the enzyme-linked immunosorbent assay (ELISA) technique that measure the interaction of vWF and collagen are an alternative analytic procedure based on a more physiological function than that of the RCo procedure. We used both assay systems in a comparative study to assess the functional activity of vWF in plasma as well as in therapeutic preparations. We measured RCo activities of plasma from healthy donors and patients with different types of von Willebrand disease (vWD) and of vWF as a drug substance in factor (F) VIII/vWF concentrates using both the aggregometric and the macroscopic methods. In addition, we measured collagen-binding activity (vWF:CB) using a recently developed commercially available CBA system. To investigate the relation between the structure and the functional activity of vWF, we isolated vWF species with different numbers of multimers from FVIII/vWF concentrates by affinity chromatography on immobilized heparin. The vWF:RCo and vWF:CB of the different fractions were measured, and the multimeric structure of vWF was analyzed by sodium dodecyl sulfate (SDS) agarose gel electrophoresis. (vWF:CB and vWF:RCo are part of the nomenclature proposed by the International Society on Thrombosis and Hemostasis Scientific and Standardization Committee [ISTH SSC] subcommittee on von Willebrand factor, in Maastricht, Germany, June 16, 2000.) Measurement of functional vWF activity by CBA can be carried out with substantially higher interassay reproducibility than can measurement of RCo. Both assay systems can be used for diagnosis and subtyping of vWD, but CBA is more sensitive than either of the two RCo methods. The analysis of vWF multimers in the different fractions obtained by affinity chromatography on heparin Sepharose showed that the activity measured both with RCo assay and CBA correlated with the degree of multimerization. Our results suggest that measurement of the functional activity of vWF by the RCo procedure can be replaced by the more reliable CBA, reflecting the physiological hemostatic activity of vWF. The CBA method appears not only to be more sensitive and easier to carry out than the RCo method is but also to have a higher reproducibility and allow better standardization.
Similar articles
-
Comparison of two von Willebrand factor collagen-binding assays with different binding affinities for low, medium, and high multimers of von Willebrand factor.Semin Thromb Hemost. 2002 Apr;28(2):139-48. doi: 10.1055/s-2002-27816. Semin Thromb Hemost. 2002. PMID: 11992237
-
von Willebrand disease in a pediatric-based population--comparison of type 1 diagnostic criteria and use of the PFA-100 and a von Willebrand factor/collagen-binding assay.Thromb Haemost. 2000 Sep;84(3):401-9. Thromb Haemost. 2000. PMID: 11019962
-
A Reliable von Willebrand factor: ristocetin cofactor enzyme-linked immunosorbent assay to differentiate between type 1 and type 2 von Willebrand disease.Semin Thromb Hemost. 2002 Apr;28(2):161-6. doi: 10.1055/s-2002-27818. Semin Thromb Hemost. 2002. PMID: 11992239
-
Von Willebrand factor collagen-binding (activity) assay in the diagnosis of von Willebrand disease: a 15-year journey.Semin Thromb Hemost. 2002 Apr;28(2):191-202. doi: 10.1055/s-2002-27821. Semin Thromb Hemost. 2002. PMID: 11992242 Review.
-
Comparative analysis and classification of von Willebrand factor/factor VIII concentrates: impact on treatment of patients with von Willebrand disease.Semin Thromb Hemost. 2006 Sep;32(6):626-35. doi: 10.1055/s-2006-949668. Semin Thromb Hemost. 2006. PMID: 16977573 Review.
Cited by
-
Correlation between von Willebrand factor antigen, von Willebrand factor ristocetin cofactor activity and factor VIII activity in plasma.J Thromb Thrombolysis. 2008 Oct;26(2):150-3. doi: 10.1007/s11239-007-0090-0. Epub 2007 Sep 3. J Thromb Thrombolysis. 2008. PMID: 17786534
-
Nanobody activator improves sensitivity of the von Willebrand factor activity assay to multimer size.J Thromb Haemost. 2024 Jul;22(7):2052-2058. doi: 10.1016/j.jtha.2024.04.015. Epub 2024 May 3. J Thromb Haemost. 2024. PMID: 38704122 Free PMC article.
-
Establishment and characterization of a new and stable collagen-binding assay for the assessment of von Willebrand factor activity.Int J Lab Hematol. 2013 Apr;35(2):170-6. doi: 10.1111/ijlh.12019. Epub 2012 Oct 29. Int J Lab Hematol. 2013. PMID: 23107512 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous