Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 May;83(5):613-27.
doi: 10.1053/apmr.2002.32309.

The amputee mobility predictor: an instrument to assess determinants of the lower-limb amputee's ability to ambulate

Affiliations

The amputee mobility predictor: an instrument to assess determinants of the lower-limb amputee's ability to ambulate

Robert S Gailey et al. Arch Phys Med Rehabil. 2002 May.

Abstract

Objectives: To describe the development of the Amputee Mobility Predictor (AMP) instrument designed to measure ambulatory potential of lower-limb amputees with (AMPPRO) and without (AMPnoPRO) the use of a prosthesis, and to test its reliability and validity.

Design: Measurement study using known groups method and concurrence with existing measures.

Setting: Academic medical center.

Participants: A convenience sample of 191 lower-limb amputee subjects who had completed prosthetic training, 24 in the reliability study (mean age +/- standard deviation, 68.3+/-17.9y, range, 28-99y) and 167 in the validity study (mean age, 54.8+/-18.6y; range, 18-100y).

Interventions: Not applicable.

Main outcome measures: Intra- and interrater reliability; construct validity by known groups method; concurrent validity by comparisons with 6-minute walk test, Comorbidity Index, age, and time since amputation; predictive validity by comparison with 6-minute walk test after controlling for other factors.

Results: Interrater reliability was.99 for subjects tested with and without their prosthesis; intrarater reliability was.96 and.97. Both the AMPnoPRO (P<.0001) and the AMPPRO scores (P<.0001) distinguished among the 4 Medicare functional classification levels. The AMP correlated strongly with 6-minute walk scores (AMPnoPRO r=.69, P<.0001; AMPPRO r=.82, P<.0001) and the amputee activity survey (AMPnoPRO r=.67, P<.0001; AMPPRO r=.77, P<.0001), and negatively correlated with age (AMPnoPRO r=-.69, P<.0001; AMPPRO r=.56, P<.0001) and comorbidity (AMPnoPRO r=-.43, P<.0001; AMPPRO r=.38, P<.0001).

Conclusion: The AMP with and without a prosthesis are reliable and valid measures for the assessment of functional ambulation in lower-limb amputee subjects.

PubMed Disclaimer

Publication types

LinkOut - more resources