. 2002 May;84(5):780-5.
doi: 10.2106/00004623-200205000-00013.

Biomechanical comparison of effects of supraspinatus tendon detachments, tendon defects, and muscle retractions

Affiliations
Comparative Study

Biomechanical comparison of effects of supraspinatus tendon detachments, tendon defects, and muscle retractions

A M Halder et al. J Bone Joint Surg Am. 2002 May.

Abstract

Background: Rotator cuff ruptures are frequently associated with loss of strength of the shoulder. However, the characteristics of the rotator cuff tear that are responsible for the loss of force generation and transmission have not yet been identified. The purpose of this study was to compare the effects of supraspinatus tendon detachments, tendon defects, and muscle retractions on in vitro force transmission by the rotator cuff to the humerus.

Methods: The rotator cuff tendons from ten cadaver shoulders were loaded proportionally to the respective cross-sectional areas of their muscles. A fiberglass rod was cemented into the medullary canal of the humerus and connected to a three-component load cell for the measurement of the forces transmitted by the rotator cuff to the humerus. This study was performed with the humerus in a hanging arm position and with various sizes of supraspinatus tendon detachments, tendon defects, and muscle retractions.

Results: Detachment or creation of a defect involving one-third or two-thirds of the supraspinatus tendon resulted in a minor reduction in the force transmitted by the rotator cuff (< or =5%), while detachment or creation of a defect involving the whole tendon resulted in a moderate reduction (11% and 17%, respectively). Simulated muscle retraction involving one-third, two-thirds, and the whole tendon resulted in losses of torque measuring 19%, 36%, and 58%, respectively. Side-to-side repair of the one-third and two-thirds defects nearly restored the force transmission capability, whereas a deficit remained after side-to-side repair following complete resection.

Conclusions: Our results support the rotator cable concept and correspond to the clinical observation that patients with a small rupture of the rotator cuff may present without a loss of shoulder strength. Muscle retraction is potentially an important factor responsible for loss of shoulder strength following large rotator cuff ruptures.

Clinical relevance: Supraspinatus muscle retraction diminishes glenohumeral abduction torque significantly more than either a defect in the tendon or a simple detachment of the tendon from the tuberosity. In cases of irreparable defects, side-to-side repair may be worthwhile to restore muscle tension and the integrity of the rotator cable.