Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2002 May 24;16(8):1119-29.
doi: 10.1097/00002030-200205240-00005.

Use of laboratory tests and clinical symptoms for identification of primary HIV infection

Affiliations
Clinical Trial

Use of laboratory tests and clinical symptoms for identification of primary HIV infection

Frederick M Hecht et al. AIDS. .

Abstract

Objective: To determine the sensitivity and specificity of symptoms, three HIV-1 RNA assays, a p24 antigen EIA and a third-generation enzyme immunoassay (EIA) antibody test for diagnosis of primary HIV infection (PHI).

Design: Prospective cohort in a university research program.

Participants: Of 258 eligible persons screened for PHI, 40 had primary/early infection (22 preseroconversion, 18 within 6 months of seroconversion) and 218 did not. Seven participants with preseroconversion HIV-1 from a second center were added for evaluating laboratory tests.

Main outcome measure: PHI, defined as a negative or indeterminate antibody test with subsequent conversion. Symptom analysis also included persons with antibody conversion of less than 6 months' duration.

Results: The symptoms most strongly associated with PHI in multivariate analysis were fever [odds ratio (OR) 5.2; 95% confidence interval (CI) 2.3-11.7] and rash (OR 4.8; 95% CI 2.4-9.8). The sensitivity and specificity, respectively, for detecting preseroconversion HIV infection were: p24 antigen, 79% and 99%; third-generation EIA, 79% and 97%; HIV-1 RNA by branched chain DNA 100% and 95%; HIV-1 RNA by polymerase chain reaction 100% and 97%; HIV-1 RNA by transcription-mediated amplification testing, 100% and 98%. False-positive HIV-1 RNA tests were not reproducible and had values < 3000 copies/ml, while only one person with confirmed PHI was in this range.

Conclusions: Rash and fever indicated the highest risk of PHI. HIV-1 RNA tests are very sensitive for PHI but false-positive results occur. False-positive results can be reduced through duplicate testing and considering tests < 5000 copies/ml as indeterminate results requiring additional testing. p24 antigen was more specific than HIV-1 RNA testing but less sensitive.

PubMed Disclaimer

Publication types

MeSH terms