Reduction of exposure to laboratory animal allergens in a research laboratory
- PMID: 12005134
- DOI: 10.1093/annhyg/mef022
Reduction of exposure to laboratory animal allergens in a research laboratory
Abstract
Objectives: The purpose of this study was to determine exposure levels in the laboratory during different tasks and evaluate the effectiveness of safety equipment used to reduce personal exposure.
Methods: Personal and stationary air samples were collected during different tasks in a laboratory animal facility in which several allergen reduction strategies had been implemented. Mouse urinary allergen concentrations were measured using a polyclonal sandwich enzyme-linked immunosorbent assay. Sera from the personnel (n = 29) were analysed every 6 months for the presence of specific antibodies against mouse and rat urinary allergens, and the staff answered questionnaires on work-related symptoms, exposure and use of respiratory protection.
Results: The highest airborne mouse allergen levels were measured during manual emptying of cages, during changing of cages on an unventilated table and during handling of male animals on an unventilated table. Automatic emptying and cleaning of cages resulted in low airborne allergen levels in the working room. Using a ventilated cage-changing wagon reduced the allergen exposure level from 77 to 17 ng/m3. The housing of animals in ventilated cabinets, with air exhausted through the cabinet, effectively prevented the release of allergens into the ambient air. The handling of animals on ventilated benches and the use of a centralized vacuum cleaner resulted in a low exposure level. Only two subjects developed specific immunoglobulin E of > 0.35 kU/l, of whom one was reduced to negative after increased use of respiratory protection.
Conclusions: Effective reduction of exposure to allergens can be achieved by several strategies, which together appear to minimize sensitization to rodents.
Similar articles
-
Reduction of exposure to laboratory animal allergens in the workplace.Clin Exp Allergy. 1997 Jul;27(7):744-51. Clin Exp Allergy. 1997. PMID: 9249266
-
Nasal air sampling used for the assessment of occupational allergen exposure and the efficacy of respiratory protection.Clin Exp Allergy. 2002 Dec;32(12):1769-75. doi: 10.1046/j.1365-2222.2002.01545.x. Clin Exp Allergy. 2002. PMID: 12653170
-
Evaluation of individually ventilated cage systems for laboratory rodents: occupational health aspects.Lab Anim. 2001 Jan;35(1):42-50. doi: 10.1258/0023677011911363. Lab Anim. 2001. PMID: 11201287
-
Controlling exposure to laboratory animal allergens.ILAR J. 2001;42(1):17-36. doi: 10.1093/ilar.42.1.17. ILAR J. 2001. PMID: 11123186 Review.
-
A risk-based approach to reducing exposure of staff to laboratory animal allergens.Lab Anim (NY). 2015 Jan;44(1):32-8. doi: 10.1038/laban.603. Lab Anim (NY). 2015. PMID: 25526057 Review.
Cited by
-
Laboratory animals and respiratory allergies: the prevalence of allergies among laboratory animal workers and the need for prophylaxis.Clinics (Sao Paulo). 2013 Jun;68(6):750-9. doi: 10.6061/clinics/2013(06)05. Clinics (Sao Paulo). 2013. PMID: 23778494 Free PMC article.
-
Animal allergens and their presence in the environment.Front Immunol. 2014 Mar 3;5:76. doi: 10.3389/fimmu.2014.00076. eCollection 2014. Front Immunol. 2014. PMID: 24624129 Free PMC article. Review.
-
Influence of 5 different caging types and the use of cage-changing stations on mouse allergen exposure.J Am Assoc Lab Anim Sci. 2014 Jul;53(4):356-63. J Am Assoc Lab Anim Sci. 2014. PMID: 25199090 Free PMC article.
-
Exposure of laboratory animal care workers to airborne mouse and rat allergens.J Am Assoc Lab Anim Sci. 2012;51(5):554-60. J Am Assoc Lab Anim Sci. 2012. PMID: 23312083 Free PMC article.
-
Effect of Room Ventilation Rates in Rodent Rooms with Direct-Exhaust IVC Systems.J Am Assoc Lab Anim Sci. 2015 Sep;54(5):521-6. J Am Assoc Lab Anim Sci. 2015. PMID: 26424250 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical