Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 May;121(5):1595-601.
doi: 10.1378/chest.121.5.1595.

Safety of pressure-volume curve measurement in acute lung injury and ARDS using a syringe technique

Affiliations

Safety of pressure-volume curve measurement in acute lung injury and ARDS using a syringe technique

Warren L Lee et al. Chest. 2002 May.

Abstract

Study objectives: To assess the safety of frequent pressure-volume (PV) curve measurement in patients with acute lung injury (ALI)/ARDS.

Design: Prospective observational study.

Setting: Academic medical-surgical critical care unit.

Patients: Consecutive patients with ALI or ARDS.

Interventions: Static inspiratory PV curves of the respiratory system were determined twice on day 1, then once daily for up to 6 days using a syringe. At each time point, three separate measurements of the PV curve were made. A 100-mL graduated syringe was used to inflate patients' lungs with 50- to 100-mL increments up to an airway pressure of 45 cm H(2)O or a total volume of 2 L; each volume step was maintained for 2 to 3 s until a plateau airway pressure was recorded. Outcome measures were mean arterial BP, heart rate (HR), and oxyhemoglobin saturation (SpO(2)) prior to and immediately after PV curve measurement. There were a priori criteria for procedure discontinuation if poorly tolerated.

Measurements and results: Eleven patients were enrolled with a total of 134 PV curves generated. SpO(2) was 93 +/- 4% (mean +/- SD) before and fell to a nadir of 89 +/- 5% during PV curve measurement (p < 0.001), but increased to 97 +/- 4% immediately afterwards (p < 0.001, before vs after). HR rose from 106 +/- 22 to 108 +/- 22 beats/min immediately after the maneuver (p < 0.001). Mean arterial BP was 93 +/- 15 mm Hg before and 100 +/- 17 mm Hg immediately afterwards (p < 0.001). During PV curve measurement, systolic BP in one patient fell to 64 mm Hg from 113 mm Hg; in another patient, SpO(2) dropped to 79% from 89%. Both changes were transient. The study was discontinued in one patient because of inability to tolerate zero positive end-expiratory pressure; in another patient, the study was discontinued because of the development of subcutaneous emphysema.

Conclusions: PV curve measurement by syringe technique is well tolerated in most patients. Nonetheless, the maneuver may cause significant changes in oxygenation and/or hemodynamics, necessitating close monitoring.

PubMed Disclaimer

Publication types

LinkOut - more resources