Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2002 May;27(3):470-8.
doi: 10.1053/jhsu.2002.32965.

The active movement scale: an evaluative tool for infants with obstetrical brachial plexus palsy

Affiliations
Comparative Study

The active movement scale: an evaluative tool for infants with obstetrical brachial plexus palsy

Christine Curtis et al. J Hand Surg Am. 2002 May.

Abstract

Newborns with peripheral nerve lesions involving the upper extremity are difficult to evaluate. The reliability of the Active Movement Scale (AMS), a tool for assessing motor function in infants with obstetrical brachial plexus palsy (OBPP), was examined in 2 complementary studies. Part A was an interrater reliability study in which 63 infants younger than 1 year with OBPP were independently evaluated by 2 physical therapists using the AMS. The scores were compared for reliability and controlled for chance agreement by using kappa statistics. Overall kappa analysis of the 15 tested movements showed a moderate strength of score agreement (kappa = 0.51). Quadratic-weighted kappa (kappa(quad)) statistics showed that 8 of the 15 movements tested were in the highest strength of agreement category (kappa(quad) = 0.81-1.00). Five movements showed substantial agreement (kappa(quad) = 0.61-0.80), and 2 movements had moderate agreement (kappa(quad) = 0.41- 0.60). The overall kappa(quad) was 0.89. Part B was a variability study designed to examine the dispersion of scores when infants with OBPP were evaluated with the AMS by multiple raters. Ten pediatric physical therapists with varying degrees of experience using the scale attended a 1(1/2)-hour instructional workshop on administration of the tool for infants with OBPP. A chain-block study design was used to obtain 30 assessments of 10 infants by 10 raters. A 2-way analysis of variance indicated that the variability of scores due to rater factors was low compared with the variability due to patient factors and that variation in scores due to rater experience was minimal. The results of part A indicate that the AMS is a reliable tool for the assessment of infants with OBPP when raters familiar with the scale are compared. The results of part B suggest that, with minimal training, raters with a range of experience using the AMS are able to reliably evaluate infants with upper-extremity paralysis.

PubMed Disclaimer

Publication types