Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2002 May 15;165(10):1377-83.
doi: 10.1164/rccm.2105013.

Systemic effect comparisons of six inhaled corticosteroid preparations

Affiliations
Clinical Trial

Systemic effect comparisons of six inhaled corticosteroid preparations

Richard J Martin et al. Am J Respir Crit Care Med. .

Abstract

The goal of this study was to establish a reliable method to evaluate systemic bioavailability and to determine equisystemic effects (microgram dose producing equal systemic cortisol suppression) of inhaled corticosteroids (ICS). Steroid naive asthma subjects (n = 156) were enrolled at six centers. A 1-week doubling dose design was used for each of six ICS and matched placebos for a total of four doses. Systemic effect was evaluated by hourly plasma cortisol concentrations (8 P.M. to 8 A.M.), 12- and 24-hour urine cortisol concentrations, and a morning blood osteocalcin. The area under the concentration-time curve for hourly cortisol concentrations was the best outcome variable to assess systemic effect. For the six ICS and matching placebos (beclomethasone-chlorofluorocarbon [CFC], budesonide dry powder inhaler [DPI], fluticasone DPI, fluticasone-CFC metered dose inhaler [MDI], flunisolide-CFC, and triamcinolone-CFC), only the placebo group and fluticasone DPI did not demonstrate a significant dose-response effect. Thus microgram comparison of all ICS could only be performed at a 10% cortisol suppression: flunisolide-CFC - 936; triamcinolone-CFC - 787; beclomethasone-CFC - 548; fluticasone DPI - 445; budesonide DPI - 268; fluticasone-CFC MDI - 111. This study represents the first step in evaluation of ICS efficacy based on equisystemic (cortisol suppression) effects of a given ICS, rather than doses judged arbitrarily to be comparable on a microgram basis.

PubMed Disclaimer

Comment in

  • Systemic effects of inhaled corticosteroids.
    Harrison TW, Tattersfield AE. Harrison TW, et al. Am J Respir Crit Care Med. 2003 Apr 1;167(7):1037-8; author reply 1038. doi: 10.1164/ajrccm.167.7.954. Am J Respir Crit Care Med. 2003. PMID: 12663345 No abstract available.

Similar articles

Cited by

MeSH terms