Disinfection of wastewater using a 20-kHz ultrasound unit
- PMID: 12043973
- DOI: 10.2175/106143002x139875
Disinfection of wastewater using a 20-kHz ultrasound unit
Abstract
The present study explored the application of a 20-kHz ultrasound unit for the disinfection of domestic wastewater. Experiments were conducted in batch with an ultrasound probe. The disinfection efficiency of fecal coliform increased with ultrasound power input from 0.003 log kill/min at 70 W/L to 1.8 log kill/min at 1250 W/L. Disinfection data are well-described by the Chick-Watson disinfection model (coefficient of dilution, n = 2.0) using ultrasound power in place of chemical concentration. Water quality did not affect disinfection efficiency significantly. Temperature increases experienced with ultrasonic treatment were significant. Attempts to control the temperature resulted in a marked decrease in disinfection efficiency. Experiments devised to quantify the role of thermal mechanisms revealed that of the total kill produced by ultrasound approximately 52% was attributed to heat, 36% to mechanical stresses associated with ultrasonically induced cavitation, and 12% to uncharacterized synergistic effects. Successful scale-up was demonstrated using a 9.3-L pilot-scale ultrasound unit, operated under flow-through conditions.
Similar articles
-
Disinfection of hospital wastewater by continuous ozonization.J Environ Sci Health A Tox Hazard Subst Environ Eng. 2003;38(12):2895-908. doi: 10.1081/ese-120025839. J Environ Sci Health A Tox Hazard Subst Environ Eng. 2003. PMID: 14672323
-
Improved wastewater disinfection by ultrasonic pre-treatment.Ultrason Sonochem. 2004 Jul;11(5):333-6. doi: 10.1016/S1350-4177(03)00156-1. Ultrason Sonochem. 2004. PMID: 15157865
-
Effect of ultrasonic pretreatment on chlorine dioxide disinfection efficiency.Ultrason Sonochem. 2011 Mar;18(2):683-8. doi: 10.1016/j.ultsonch.2010.08.008. Epub 2010 Aug 18. Ultrason Sonochem. 2011. PMID: 20829088
-
Fecal coliform accumulation within a river subject to seasonally-disinfected wastewater discharges.Water Res. 2010 Sep;44(16):4776-82. doi: 10.1016/j.watres.2010.05.060. Epub 2010 Jun 12. Water Res. 2010. PMID: 20580053
-
Chemical disinfection of secondary municipal wastewater effluents: Optimizing CT dose and tailing effects through high-intensity mixing.Water Environ Res. 2025 Apr;97(4):e70066. doi: 10.1002/wer.70066. Water Environ Res. 2025. PMID: 40166971 Free PMC article.
Cited by
-
Escherichia coli K-12 Transcriptomics for Assessing the Mechanism of Action of High-Power Ultrasound.Microorganisms. 2023 Nov 14;11(11):2768. doi: 10.3390/microorganisms11112768. Microorganisms. 2023. PMID: 38004779 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources