Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Feb;14(1):37-44.
doi: 10.1111/j.1540-8183.2001.tb00709.x.

Transcatheter closure of atrial septal defects in children & adults using the Amplatzer Septal Occluder

Affiliations

Transcatheter closure of atrial septal defects in children & adults using the Amplatzer Septal Occluder

A Omeish et al. J Interv Cardiol. 2001 Feb.

Abstract

We are reporting the worldwide experience in closing atrial septal defects (ASDs) in children and adults using the Amplatzer Septal Occluder (ASO) as of July 2000. The outcome measures were safety and efficacy with special emphasis on: (1) immediate success of the ASD closure as measured by transesophageal echocardiography (TEE), (2) short- and medium-term follow-up at 24 hours and 1 and 3 months and long-term follow-up at 1, 2, and 3 years as assessed by transthoracic echocardiography (TTE); and (3) the incidence of complications. In all, 3580 procedures were performed in 3535 patients. In 75 patients, the device was not implanted for variety of reasons; 3460 patients received a single ASO device and 45 received two devices for multiple ASDs. The median age of the patients was 12.1 year, (range, 10 days-88 years, the median weight was 41.0 kg (range, 2.4-137 kg) and the median Qp/Qs ratio was 2 (range, 0.3-10). The median size of ASD by TEE was 14 mm (range, 1-38 mm) and the median stretched diameter was 18 mm (range, 4-44 mm). The median size of device implanted was 18 mm (range, 4-40 mm). The median fluoroscopy time was 17.1 minutes (range, 0.0-194.0 minutes). The immediate success rate including those patients with complete closure, trivial residual shunt, or with small residual shunt was 97.4%. This increased to 99.2% and 100% at 3 months and 3 years, respectively. Minor complications were encountered in 2.8% of procedures, while serious complications occurred in less than 0.3% of the cases. There were no device related deaths. We conclude that the ASO is a safe and effective device for catheter closure of small to large ASDs up to a stretched diameter of 40 mm in children and adults with very high short-, medium, and long-term success rates.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources