Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Jun 15;305(2):206-13.
doi: 10.1006/abio.2002.5662.

Determination of 5-methyltetrahydrofolate (13C-labeled and unlabeled) in human plasma and urine by combined liquid chromatography mass spectrometry

Affiliations

Determination of 5-methyltetrahydrofolate (13C-labeled and unlabeled) in human plasma and urine by combined liquid chromatography mass spectrometry

David J Hart et al. Anal Biochem. .

Abstract

The association of folates with the prevention of neural tube defects and reduced risk of other chronic diseases has stimulated interest in the development of techniques for the study of their bioavailability in humans. Stable isotope protocols differentiate between oral and/or intravenous test doses of folate and natural levels of folate already present in the body. An liquid chromatography/mass spectrometry (LC/MS) procedure is described that has been validated for the determination of [13C]5-methyltetrahydropteroyl monoglutamic acid ([13C]5-CH3H4PteGlu) in plasma and urine, following oral dosing of volunteers with different labeled folates. Folate binding protein affinity columns were used for sample purification prior to LC/MS determination. Chromatographic separation was achieved using a Superspher 100RP18 (4 microm) column and mobile phase of 0.1 mol/L acetic acid (pH 3.3):acetonitrile (90:10; 250 microL/min). Selected ion monitoring was conducted on the [M-H](-) ion: m/z 458 and 459 for analyzing 5-CH3H4PteGlu; m/z 464 [M+6-H](-) to determine 5-CH3H4PteGlu derived from the label dose; m/z 444 for analysis of 2H4PteGlu internal standard, and m/z 446 and 478 to confirm that there was no direct absorption of unmetabolized compounds. Calibration was linear over the range 0-9 x 10(-9) mol/L; the limits of detection and quantification were 0.2 x 10(-9) and 0.55 x 10(-9) mol/L, respectively. The mean coefficient of variation of the ratios (m/z 463/458) was 7.4%. The method has potential applications for other key folates involved in one-carbon metabolism.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources