Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2002 Apr:95 Spec No 5:31-9.

[Endocavitary ablation for arrhythmias. New modalities of radiofrequency applications. New energy types]

[Article in French]
Affiliations
  • PMID: 12055754
Review

[Endocavitary ablation for arrhythmias. New modalities of radiofrequency applications. New energy types]

[Article in French]
B Cauchemez et al. Arch Mal Coeur Vaiss. 2002 Apr.

Abstract

Radiofrequency remains the reference energy type for catheter ablation of rhythm disorders. In the classic indications, which are atrial flutter or tachycardia, nodal re-entry and Wolff-Parkinson-White syndrome, this energy source has the best cost-efficiency-safety ratio, subject to strict conditions of use. Some new modalities of application have further improved performance, especially active irrigation of the electrode which allows induction of deeper lesions which is very useful for the ablation of difficult atrial flutters, epicardial fascicles of Kent and ischaemic ventricular tachycardias. The only emerging alternative energy type, in the framework of classical ablation, is cold, for which the principal advantages are the homogenous and slightly thrombogenic character for the lesion involved, and the possibility of reversible applications tests which are especially useful in the ablation of structures at risk. The situation is more open-ended concerning research on ablation for atrial fibrillation or the so-called new energy types, such as ultrasound and laser, whilst recognising a renewal in interest, especially for circumferential ablation of the pulmonary veins to isolate the ectopic venous foci. Mechanical energy such as luminous energy is emitted across a catheter balloon deployed at the orifice of the vein, perpendicular to its axis, aiming to reach a continuous circumferential lesion with a minimum of applications. Equally radiofrequency has been undergoing significant evolution for this application, such as by the development of porous catheter balloons with a liquid electrode, as well as by the development of deployable circumferential catheters. Ablation is use for atrial fibrillation, by endocavity atrial segmentation remains a field of research in which radiofrequency retains an important place. It is delivered via multi-electrode catheters according to the new application modalities, either pulsed or by phase interval, which secure better efficacy by better continuity of the line of block. Research is equally underway on the use of microwaves and cold in this application.

PubMed Disclaimer

LinkOut - more resources