Atrial cardiomyoplasty in a Fontan circulation
- PMID: 12062264
- DOI: 10.1016/s1010-7940(02)00063-5
Atrial cardiomyoplasty in a Fontan circulation
Abstract
Introduction: The Fontan circulation is a direct connection between the systemic veins and the pulmonary artery (PA). Consequently, the pulmonary flow is passive due to the gradient between the right and left atrial pressure. In patients with increased pulmonary vascular resistance, the surgical procedure of atrio-pulmonary connection is therefore prone to failure. The goal of this experiment was to increase the pulmonary flow in an experimental model of a Fontan circulation by performing a right atrial cardiomyoplasty (ACMP).
Methods: In 19 Foxhounds the left m. latissimus dorsi (LD) was mobilised and transferred as a pedicle into the chest. After sternotomy a 'Fontan circulation' was created under cardiopulmonary bypass (CPB) by connecting the right atrium (RA) with the PA by a valveless conduit. The tricuspid valve was closed with a patch. In 11 dogs (group 1) a valve was implanted in the inferior vena cava (IVC) and pulmonary inflow impedance was increased by partial occlusion of the conduit to a gradient of 10 mmHg between RA and PA. In the other eight dogs (group 2) no valve was implanted, but flowmeters were placed in the IVC and the superior vena cava (SVC). In all dogs the RA was enlarged by a fascia lata patch before the LD was wrapped over the RA and stimulated synchronously to the R-wave with burst impulses.
Results: After coming off CPB, relatively high central venous pressures (22.5+/-5.8 mmHg) were necessary to maintain haemodynamic stability. With LD-stimulation in a 1:3 mode in group 1, RA pressure (P) increased from 23.1+/-7.7 to 45+/-10.5 mmHg (P<0.001), pulmonary atrial pressure (PAP) from 15.5+/-4.3 to 25.5+/-7.6 mmHg (P<0.001) and central venous pressure increased to 33.1+/-11.3 mmHg (P<0.05). Stroke volume increase from 11.4+/-4.7 to 17.2+/-4.3 ml and peak conduit-flow from 1286.3+/-880.3 to 2329+/-1173 ml/min (all P<0.001). In a 1:1 stimulation mode a pulsatile pressure/flow profile was obtained in the PA-conduit. Furthermore, at higher frequencies of about 120 beats/min muscle relaxation was still fast enough as not to interfere with the RA filling. In group 2 caval flow without stimulation occurred mainly during diastole. However, with LD-stimulation, a strong backflow into IVC and SVC was observed resulting in a less pronounced pressure/flow increase in the PA.
Conclusions: Our experimental model demonstrates the possibility of a 'ventricularisation' of the RA by using the force of the LD. However, the haemodynamic benefit of ACMP was achieved only, when a valve was implanted in the ICV.
Similar articles
-
Right ventricular dynamic cardiomyoplasty for the univentricular heart with pulmonary hypertension.Jpn J Thorac Cardiovasc Surg. 2001 Apr;49(4):207-15. doi: 10.1007/BF02913517. Jpn J Thorac Cardiovasc Surg. 2001. PMID: 11355252
-
Feasibility of creating a novel animal heart model to test transcatheter techniques for a cavocaval connection that mimics a Fontan completion.J Thorac Cardiovasc Surg. 2013 Aug;146(2):408-12. doi: 10.1016/j.jtcvs.2012.09.059. Epub 2012 Oct 23. J Thorac Cardiovasc Surg. 2013. PMID: 23102683
-
Postsurgical comparison of pulsatile hemodynamics in five unique total cavopulmonary connections: identifying ideal connection strategies.Ann Thorac Surg. 2013 Oct;96(4):1398-1404. doi: 10.1016/j.athoracsur.2013.05.035. Epub 2013 Jul 30. Ann Thorac Surg. 2013. PMID: 23910632
-
Extracardiac conduit variation of the Fontan procedure.Adv Card Surg. 2000;12:175-98. Adv Card Surg. 2000. PMID: 10949650 Review.
-
Extracardiac Fontan operation without cardiopulmonary bypass.J Cardiovasc Surg (Torino). 2006 Dec;47(6):699-704. J Cardiovasc Surg (Torino). 2006. PMID: 17043618 Review.
Cited by
-
In Silico Evaluation of a Self-powered Venous Ejector Pump for Fontan Patients.Cardiovasc Eng Technol. 2023 Jun;14(3):428-446. doi: 10.1007/s13239-023-00663-5. Epub 2023 Mar 6. Cardiovasc Eng Technol. 2023. PMID: 36877450 Free PMC article.
-
Role and Applications of Experimental Animal Models of Fontan Circulation.J Clin Med. 2024 Apr 29;13(9):2601. doi: 10.3390/jcm13092601. J Clin Med. 2024. PMID: 38731130 Free PMC article. Review.
-
Development of a thermodynamic control system for the Fontan circulation pulsation device using shape memory alloy fibers.J Artif Organs. 2015 Sep;18(3):199-205. doi: 10.1007/s10047-015-0827-z. Epub 2015 Apr 18. J Artif Organs. 2015. PMID: 25894077
-
In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients.J Thorac Cardiovasc Surg. 2018 Jul;156(1):292-301.e7. doi: 10.1016/j.jtcvs.2018.02.088. Epub 2018 Mar 11. J Thorac Cardiovasc Surg. 2018. PMID: 29666009 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials