Cardiac resynchronization in chronic heart failure
- PMID: 12063368
- DOI: 10.1056/NEJMoa013168
Cardiac resynchronization in chronic heart failure
Abstract
Background: Previous studies have suggested that cardiac resynchronization achieved through atrial-synchronized biventricular pacing produces clinical benefits in patients with heart failure who have an intraventricular conduction delay. We conducted a double-blind trial to evaluate this therapeutic approach.
Methods: Four hundred fifty-three patients with moderate-to-severe symptoms of heart failure associated with an ejection fraction of 35 percent or less and a QRS interval of 130 msec or more were randomly assigned to a cardiac-resynchronization group (228 patients) or to a control group (225 patients) for six months, while conventional therapy for heart failure was maintained. The primary end points were the New York Heart Association functional class, quality of life, and the distance walked in six minutes.
Results: As compared with the control group, patients assigned to cardiac resynchronization experienced an improvement in the distance walked in six minutes (+39 vs. +10 m, P=0.005), functional class (P<0.001), quality of life (-18.0 vs. -9.0 points, P= 0.001), time on the treadmill during exercise testing (+81 vs. +19 sec, P=0.001), and ejection fraction (+4.6 percent vs. -0.2 percent, P<0.001). In addition, fewer patients in the group assigned to cardiac resynchronization than control patients required hospitalization (8 percent vs. 15 percent) or intravenous medications (7 percent vs. 15 percent) for the treatment of heart failure (P<0.05 for both comparisons). Implantation of the device was unsuccessful in 8 percent of patients and was complicated by refractory hypotension, bradycardia, or asystole in four patients (two of whom died) and by perforation of the coronary sinus requiring pericardiocentesis in two others.
Conclusions: Cardiac resynchronization results in significant clinical improvement in patients who have moderate-to-severe heart failure and an intraventricular conduction delay.
Comment in
-
Cardiac-resynchronization therapy for heart failure.N Engl J Med. 2002 Jun 13;346(24):1902-5. doi: 10.1056/NEJMed020028. N Engl J Med. 2002. PMID: 12063376 No abstract available.
-
Cardiac resynchronization was effective for moderate-to-severe heart failure with intraventricular conduction delay.ACP J Club. 2002 Nov-Dec;137(3):82. ACP J Club. 2002. PMID: 12418822 No abstract available.
-
Cardiac resynchronization therapy for heart failure.N Engl J Med. 2002 Nov 28;347(22):1803-4; author reply 1803-4. doi: 10.1056/NEJM200211283472216. N Engl J Med. 2002. PMID: 12456861 No abstract available.
-
Cardiac resynchronization therapy for heart failure.N Engl J Med. 2002 Nov 28;347(22):1803-4; author reply 1803-4. N Engl J Med. 2002. PMID: 12462232 No abstract available.
Similar articles
-
Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay.N Engl J Med. 2001 Mar 22;344(12):873-80. doi: 10.1056/NEJM200103223441202. N Engl J Med. 2001. PMID: 11259720 Clinical Trial.
-
Impact of cardiac resynchronization therapy on exercise performance, functional capacity, and quality of life in systolic heart failure with QRS prolongation: COMPANION trial sub-study.J Card Fail. 2008 Feb;14(1):9-18. doi: 10.1016/j.cardfail.2007.08.003. J Card Fail. 2008. PMID: 18226768 Clinical Trial.
-
Randomized comparison of simultaneous biventricular stimulation versus optimized interventricular delay in cardiac resynchronization therapy. The Resynchronization for the HemodYnamic Treatment for Heart Failure Management II implantable cardioverter defibrillator (RHYTHM II ICD) study.Am Heart J. 2006 May;151(5):1050-8. doi: 10.1016/j.ahj.2005.08.019. Am Heart J. 2006. PMID: 16644335 Clinical Trial.
-
Does cardiac resynchronisation therapy improve survival and quality of life in patients with end-stage heart failure?Interact Cardiovasc Thorac Surg. 2008 Dec;7(6):1141-6. doi: 10.1510/icvts.2008.183707. Epub 2008 Jun 9. Interact Cardiovasc Thorac Surg. 2008. PMID: 18541605 Review.
-
Cardiac resynchronization therapy: device-based medicine for heart failure.J Card Surg. 2004 May-Jun;19(3):270-4. doi: 10.1111/j.0886-0440.2004.04081.x. J Card Surg. 2004. PMID: 15151661 Review.
Cited by
-
[Coronary sinus devices for treatment of functional mitral valve regurgitation. Solution or dead end?].Herz. 2013 Aug;38(5):490-500. doi: 10.1007/s00059-013-3866-3. Herz. 2013. PMID: 23836012 Review. German.
-
Magnetoelectric Bio-Implants Powered and Programmed by a Single Transmitter for Coordinated Multisite Stimulation.IEEE J Solid-State Circuits. 2022 Mar;57(3):818-830. doi: 10.1109/jssc.2021.3129993. Epub 2021 Dec 8. IEEE J Solid-State Circuits. 2022. PMID: 36275505 Free PMC article.
-
Defining Left Bundle Branch Block Patterns in Cardiac Resynchronisation Therapy: A Return to His Bundle Recordings.Arrhythm Electrophysiol Rev. 2020 Jun 3;9(1):28-33. doi: 10.15420/aer.2019.12. Arrhythm Electrophysiol Rev. 2020. PMID: 32637117 Free PMC article. Review.
-
Optimizing exercise testing-based risk stratification to predict poor prognosis after acute heart failure.ESC Heart Fail. 2023 Apr;10(2):895-906. doi: 10.1002/ehf2.14240. Epub 2022 Dec 2. ESC Heart Fail. 2023. PMID: 36460605 Free PMC article.
-
Predictors for Super-Responders in Cardiac Resynchronization Therapy.Am J Ther. 2024 Jan-Feb 01;31(1):e13-e23. doi: 10.1097/MJT.0000000000001692. Epub 2023 Jan 10. Am J Ther. 2024. PMID: 38231577 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials