Update on intrapartum fetal pulse oximetry
Abstract
This article examines the current status of fetal pulse oximetry (FPO) as a means of intrapartum assessment of fetal wellbeing. FPO has been developed to a stage where it is a safe and accurate indicator of intrapartum fetal oxygenation. In general, sliding the FPO sensor along the examiner's fingers and through the cervix, to lie alongside the fetal cheek or temple is easy The recent publication of a randomised controlled trial (RCT) of FPO versus conventional intrapartum monitoring has validated its use to reduce caesarean section rates for nonreassuring fetal status. An Australian multicentre RCT is currently underway. Maternal satisfaction rates with FPO are high. FPO may be used during labour when the electronic fetal heart rate trace is nonreassuring or when conventional monitoring is unreliable, such as with fetal arrhythmias. If the fetal oxygen saturation (FSpO2) values are < 30%, prompt obstetric intervention is indicated, such as fetal scalp blood sampling or delivery FSpO2 monitoring should not form the sole basis of intrapartum fetal welfare assessment. Rather, the whole clinical picture should be considered.
Similar articles
-
Intrapartum oximetry of the fetus.Anesth Analg. 2007 Dec;105(6 Suppl):S59-S65. doi: 10.1213/01.ane.0000268493.90073.f3. Anesth Analg. 2007. PMID: 18048901 Review.
-
Reevaluation of intrapartum fetal monitoring using fetal oximetry: A review.J Obstet Gynaecol Res. 2018 Dec;44(12):2127-2134. doi: 10.1111/jog.13761. Epub 2018 Aug 6. J Obstet Gynaecol Res. 2018. PMID: 30084196 Review.
-
Intrapartum management of nonreassuring fetal heart rate patterns: a randomized controlled trial of fetal pulse oximetry.Am J Obstet Gynecol. 2004 Dec;191(6):1989-95. doi: 10.1016/j.ajog.2004.04.036. Am J Obstet Gynecol. 2004. PMID: 15592281 Clinical Trial.
-
[Continuous monitoring of fetal oxygen saturation (FSpO2) using intrapartum fetal pulse oximetry (IFPO) in the diagnosis of acute fetal hypoxia].Ceska Gynekol. 2000 Jul;65(4):224-30. Ceska Gynekol. 2000. PMID: 11039226 Czech.
-
Fetal pulse oximetry.Clin Obstet Gynecol. 2011 Mar;54(1):66-73. doi: 10.1097/GRF.0b013e31820a0f71. Clin Obstet Gynecol. 2011. PMID: 21278503
Cited by
-
Does the use of higher versus lower oxygen concentration improve neurodevelopmental outcomes at 18-24 months in very low birthweight infants?Trials. 2024 Apr 4;25(1):237. doi: 10.1186/s13063-024-08080-2. Trials. 2024. PMID: 38576007 Free PMC article.
-
Higher versus Lower Oxygen Concentration during Respiratory Support in the Delivery Room in Extremely Preterm Infants: A Pilot Feasibility Study.Children (Basel). 2021 Oct 20;8(11):942. doi: 10.3390/children8110942. Children (Basel). 2021. PMID: 34828655 Free PMC article.
-
Recovering fetal signals transabdominally through interferometric near-infrared spectroscopy (iNIRS).Biomed Opt Express. 2023 Oct 31;14(11):6031-6047. doi: 10.1364/BOE.500898. eCollection 2023 Nov 1. Biomed Opt Express. 2023. PMID: 38021126 Free PMC article.
-
Reducing Brain Injury of Preterm Infants in the Delivery Room.Front Pediatr. 2018 Oct 16;6:290. doi: 10.3389/fped.2018.00290. eCollection 2018. Front Pediatr. 2018. PMID: 30386757 Free PMC article. Review.
-
Fetal pulse oximetry for fetal assessment in labour.Cochrane Database Syst Rev. 2014 Oct 7;2014(10):CD004075. doi: 10.1002/14651858.CD004075.pub4. Cochrane Database Syst Rev. 2014. PMID: 25287809 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources