Monitoring intravascular volumes for postoperative volume therapy
- PMID: 12074419
- DOI: 10.1017/s0265021502000467
Monitoring intravascular volumes for postoperative volume therapy
Abstract
Background and objective: The feasibility of monitoring measured intravascular volumes and the cardiac filling pressures were compared to reflect the optimal volume status of postoperative patients.
Methods: In a prospective clinical study, 14 hypovolaemic adult patients were included after cardiac surgery. All patients received 1,000 mL hydroxyethyl starch after meeting the authors' criteria for hypovolaemia. Pressures were measured by use of a pulmonary artery catheter and volumes were determined by double-indicator dilution technique.
Results: Stroke volume index (SVI), central venous pressure (CVP), pulmonary artery occlusion pressure (PAOP), intrathoracic blood volume index (ITBVI) and total circulating blood volume (TBVIcirc) increased significantlyaftervolumeloading(30.7 +/- 9.8 to 41.7 +/- 9.6 mLm(-2), 4.9 +/- 1.7 to 9.1 +/- 2.3mmHg, 6.6 +/- 1.3 to 10.6 +/- 1.9 mmHg, 858 +/- 255 to 965 +/- 163 mLm(-2), and 1,806 +/- 502 to 2,110 +/- 537 mLm(-2), respectively). During the subsequent 1 h steady-state period, CVP and PAOP decreased significantly (9.1 +/- 2.2 to 7.4 +/- 2.2 mmHg and 10.6 +/- 1.9 to 9.2 +/- 2.0 mmHg, respectively), whereas SVI and intravascular volumes remained unchanged. The changes of CVP and PAOP did not correlate with changes in stroke volume during volume loading (r2 = 0.06 and 0.03, respectively) and during steady-state (r2 = 0.17 and 0.00 respectively). On the other hand, a significant correlation was found between changes of the intrathoracic blood volume and changes in stroke volume during the volume loading (r2 = 0.67) and also during the steady-state phase (r2 = 0.83).
Conclusions: Intrathoracic blood volume reflects more accurately the preload dependency of cardiac output in postoperative patients than left/right-sided cardiac filling pressures.
Similar articles
-
Central venous pressure, pulmonary artery occlusion pressure, intrathoracic blood volume, and right ventricular end-diastolic volume as indicators of cardiac preload.J Crit Care. 1996 Dec;11(4):180-8. doi: 10.1016/s0883-9441(96)90029-5. J Crit Care. 1996. PMID: 8977994
-
Relative value of pressures and volumes in assessing fluid responsiveness after valvular and coronary artery surgery.Eur J Cardiothorac Surg. 2009 Jan;35(1):62-8. doi: 10.1016/j.ejcts.2008.08.012. Epub 2008 Oct 1. Eur J Cardiothorac Surg. 2009. PMID: 18835782
-
Perioperative intra- and extravascular volume in liver transplant recipients.Transplant Proc. 2011 May;43(4):1098-102. doi: 10.1016/j.transproceed.2011.03.022. Transplant Proc. 2011. PMID: 21620062
-
[Assessment of volume responsiveness in mechanically ventilated patients].Anaesthesist. 2003 Nov;52(11):1005-7, 1010-3. doi: 10.1007/s00101-003-0600-1. Anaesthesist. 2003. PMID: 14992086 Review. German.
-
Hemodynamic monitoring.Minerva Anestesiol. 2002 Apr;68(4):219-25. Minerva Anestesiol. 2002. PMID: 12024086 Review.
Cited by
-
Assessing the left ventricular systolic function at the bedside: the role of transpulmonary thermodilution-derived indices.Anesthesiol Res Pract. 2011;2011:927421. doi: 10.1155/2011/927421. Epub 2011 Jul 27. Anesthesiol Res Pract. 2011. PMID: 21808645 Free PMC article.
-
Perioperative monitoring of circulating and central blood volume in cardiac surgery by pulse dye densitometry.Intensive Care Med. 2004 Nov;30(11):2053-9. doi: 10.1007/s00134-004-2445-8. Epub 2004 Sep 18. Intensive Care Med. 2004. PMID: 15378241
-
Cardiac filling volumes versus pressures for predicting fluid responsiveness after cardiovascular surgery: the role of systolic cardiac function.Crit Care. 2011;15(1):R73. doi: 10.1186/cc10062. Epub 2011 Feb 25. Crit Care. 2011. PMID: 21352541 Free PMC article. Clinical Trial.
-
Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients.Intensive Care Med. 2007 Jan;33(1):96-103. doi: 10.1007/s00134-006-0404-2. Epub 2006 Nov 21. Intensive Care Med. 2007. PMID: 17119923
-
Comparison of goal-directed hemodynamic optimization using pulmonary artery catheter and transpulmonary thermodilution in combined valve repair: a randomized clinical trial.Crit Care Res Pract. 2012;2012:821218. doi: 10.1155/2012/821218. Epub 2012 Apr 30. Crit Care Res Pract. 2012. PMID: 22611489 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical