Clinical implementation of intensity-modulated radiation therapy
- PMID: 12074468
- DOI: 10.1016/s0958-3947(02)00099-7
Clinical implementation of intensity-modulated radiation therapy
Abstract
The clinical implementation of intensity-modulated radiation therapy (IMRT) is a complex process because of the introduction of new treatment planning algorithms and beam delivery systems compared to conventional 3-dimensional conformal radiation therapy (3D-CRT) and the lack of established national performance protocols. IMRT uses an inverse-planning algorithm to create nonuniform fields that are only deliverable through a newly designed beam-modulating delivery system. The intent of this paper is to describe our experience and to elucidate the new clinical procedures that must be executed to have a successful IMRT program. Patients who undergo IMRT at our institution are immobilized and simulated before proceeding to computed tomography scan for patient data acquisition. Treatment planning involves the use of different prescription dose formats and different planning techniques compared to 3D-CRT. The desired dose goals for the target and sensitive structures must be specified before initiating the planning process, which is computer intensive. After the plan is completed, the delivery instructions are transferred to the delivery system via either a floppy disk for MIMiC-based IMRT or through the network for MLC-based IMRT. Target localizations are carried out using orthogonal radiographs. Ultrasound imaging system (BAT) is used to localize the prostate. Dose validation is performed using films, ion chambers or dose-calculation-based techniques.
Similar articles
-
Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: a strategy for large-scale implementation for the treatment of carcinoma of the prostate.Int J Radiat Oncol Biol Phys. 1997 Nov 1;39(4):863-73. doi: 10.1016/s0360-3016(97)00458-6. Int J Radiat Oncol Biol Phys. 1997. PMID: 9369136
-
Potential for reduced toxicity and dose escalation in the treatment of inoperable non-small-cell lung cancer: a comparison of intensity-modulated radiation therapy (IMRT), 3D conformal radiation, and elective nodal irradiation.Int J Radiat Oncol Biol Phys. 2003 Nov 1;57(3):875-90. doi: 10.1016/s0360-3016(03)00743-0. Int J Radiat Oncol Biol Phys. 2003. PMID: 14529795
-
Clinical implementation of intensity-modulated arc therapy.Int J Radiat Oncol Biol Phys. 2002 Jun 1;53(2):453-63. doi: 10.1016/s0360-3016(02)02777-3. Int J Radiat Oncol Biol Phys. 2002. PMID: 12023150 Clinical Trial.
-
Intensity-modulated radiotherapy: current status and issues of interest.Int J Radiat Oncol Biol Phys. 2001 Nov 15;51(4):880-914. doi: 10.1016/s0360-3016(01)01749-7. Int J Radiat Oncol Biol Phys. 2001. PMID: 11704310 Review.
-
Dose to normal tissues outside the radiation therapy patient's treated volume: a review of different radiation therapy techniques.Health Phys. 2008 Nov;95(5):666-76. doi: 10.1097/01.HP.0000326342.47348.06. Health Phys. 2008. PMID: 18849701 Review.
Cited by
-
Volumetric modulated arc therapy: a review of current literature and clinical use in practice.Br J Radiol. 2011 Nov;84(1007):967-96. doi: 10.1259/bjr/22373346. Br J Radiol. 2011. PMID: 22011829 Free PMC article. Review.
-
Eight years of IMRT quality assurance with ionization chambers and film dosimetry: experience of the Montpellier Comprehensive Cancer Center.Radiat Oncol. 2011 Jul 20;6:85. doi: 10.1186/1748-717X-6-85. Radiat Oncol. 2011. PMID: 21774795 Free PMC article.
-
Factors affecting the implementation of complex and evolving technologies: multiple case study of intensity-modulated radiation therapy (IMRT) in Ontario, Canada.BMC Health Serv Res. 2011 Jul 31;11:178. doi: 10.1186/1472-6963-11-178. BMC Health Serv Res. 2011. PMID: 21801450 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials