A simple method for tracer containment testing of hospital isolation rooms
- PMID: 12083168
- DOI: 10.1080/10473220290035688
A simple method for tracer containment testing of hospital isolation rooms
Abstract
A simple method for tracer containment testing of hospital isolation rooms is presented. The method does not require any equipment setup in tested rooms and can be completed in approximately one-half hour per room. Tracer samples are taken at specified time intervals in the corridor outside of an isolation room and analyzed on a portable gas chromatograph system. Results are presented from tracer testing of two isolation rooms in two different hospitals. One isolation room had a significant negative pressure differential between room and corridor, and the other isolation room was not at negative pressure. A small quantity of sulfur hexafluoride gas was injected manually from a polyethylene syringe over a bed in an isolation room. Tracer concentrations were thereafter measured in the corridor adjacent to the room at 5-minute intervals for 20 minutes after the injection, yielding a quantitative measure of leakage of the tracer from the isolation room. Finally, measuring the tracer concentration in the isolation room 30 minutes after injection yielded an indication of how effectively the ventilation system removed a contaminant released at the position of the bed. The results show that an instantaneous release of a small quantity of tracer gas in an isolation room yields tracer concentrations in the corridor outside of the room that are within the analytical range of the measuring equipment both for a properly functioning isolation room and an improperly functioning isolation room, and thus that the method is well-suited for studying containment in hospital isolation rooms. Possible practical applications of the method are discussed.
Similar articles
-
Containment testing of isolation rooms.J Hosp Infect. 2004 Jul;57(3):228-32. doi: 10.1016/j.jhin.2004.01.032. J Hosp Infect. 2004. PMID: 15236852
-
A simple and inexpensive method for determining the effective ventilation rate in a negatively pressurized room using airborne particles as a tracer.Appl Occup Environ Hyg. 2002 Oct;17(10):704-10. doi: 10.1080/10473220290096195. Appl Occup Environ Hyg. 2002. PMID: 12363211
-
An efficient analytical method for particle counting in evaluating airborne infectious isolation containment using fluorescent microspheres.J Occup Environ Hyg. 2008 Apr;5(4):271-7. doi: 10.1080/15459620801935056. J Occup Environ Hyg. 2008. PMID: 18286424
-
Considerations on isolation rooms and alternative pressure ventilation systems.Ann Ig. 2004 Nov-Dec;16(6):777-801. Ann Ig. 2004. PMID: 15697008 Review.
-
Packing room cleanliness studied.Health Estate. 2005 Jan;59(1):54-7. Health Estate. 2005. PMID: 15688991 Review.
Cited by
-
Potential airborne pathogen transmission in a hospital with and without surge control ventilation system modifications.Build Environ. 2016 Sep;106:175-180. doi: 10.1016/j.buildenv.2016.06.029. Epub 2016 Jun 25. Build Environ. 2016. PMID: 32287965 Free PMC article.
-
Hospital and community acquired infection and the built environment--design and testing of infection control rooms.J Hosp Infect. 2007 Jun;65 Suppl 2:43-9. doi: 10.1016/S0195-6701(07)60014-0. J Hosp Infect. 2007. PMID: 17540241 Free PMC article.
-
Different types of door-opening motions as contributing factors to containment failures in hospital isolation rooms.PLoS One. 2013 Jun 24;8(6):e66663. doi: 10.1371/journal.pone.0066663. Print 2013. PLoS One. 2013. PMID: 23826109 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Medical